Datasheet Texas Instruments BUF634UE4

ManufacturerTexas Instruments
SeriesBUF634
Part NumberBUF634UE4
Datasheet Texas Instruments BUF634UE4

250mA High-Speed Buffer 8-SOIC -40 to 125

Datasheets

BUF634 250-mA High-Speed Buffer datasheet
PDF, 1.2 Mb, Revision: A, File published: Nov 25, 2015
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Packaging

Pin88
Package TypeDD
Industry STD TermSOICSOIC
JEDEC CodeR-PDSO-GR-PDSO-G
Package QTY7575
CarrierTUBETUBE
Device Marking634UBUF
Width (mm)3.913.91
Length (mm)4.94.9
Thickness (mm)1.581.58
Pitch (mm)1.271.27
Max Height (mm)1.751.75
Mechanical DataDownloadDownload

Parametrics

Diff Gain0.4 %
Diff Phase0.1 deg
Number of Channels1
Operating Temperature Range-40 to 125 C
Output Current(Typ)250 mA
Package GroupSOIC
Package Size: mm2:W x L8SOIC: 29 mm2: 6 x 4.9(SOIC) PKG
RatingCatalog
Vs(Max)36 V
Vs(Min)4.5 V

Eco Plan

RoHSCompliant

Application Notes

  • Add Current Limit to the BUF634
    PDF, 63 Kb, File published: Sep 27, 2000
    Modern buffer amplifiers, such as the BUF634, are often used with op amps to drive high-current demand loads such as cables or eletro-mechanical devices. BUF634 features internal overload protection to prevent its destruction under fault conditions. Internal current limit protects circuitry and wirebonds from excessive current. Internal over-temp shut down protects the device from excessive temper
  • Combining an Amplifier with the BUF634
    PDF, 72 Kb, File published: Oct 2, 2000
    The following application note descibes a combination using an op amp with the high-speed buffer BUF634 located in its feedback loop. Depending upon the op amp selected, large signals with output currents of over 500mA into the MHz range can be attained.
  • Power Amplifier Stress and Power Handling Limitations
    PDF, 55 Kb, File published: Sep 27, 2000
    To achieve reliable power amplifier designs you must consider the stress on the amplifier compared to its power handling limitations. Power handling limits are specified by the Safe Operating Area (SOA) curves of the power amp. Stress on the amplifier depends on amplifier load and signal conditions which can be evaluated with straightforward techniques.

Model Line

Manufacturer's Classification

  • Semiconductors > Amplifiers > Special Function Amplifiers > Video Amplifiers
EMS supplier