RadioLocman.com Electronics ru
Advanced Search +
  

Datasheet Texas Instruments ADS1248IPWR

Texas Instruments ADS1248IPWR

Manufacturer:Texas Instruments
Series:ADS1248
Part Number:ADS1248IPWR

24-Bit, 2kSPS, 8-Ch, Delta-Sigma ADC for Precision Sensor Measurement 28-TSSOP -40 to 105

Datasheets

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Eco Plan

RoHSCompliant
Pb FreeYes

Parametrics

# Input Channels8
Analog Voltage AVDD(Max)(V)5.25
Analog Voltage AVDD(Min)(V)2.7
Approx. Price (US$)4.95 | 1ku
ArchitectureDelta-Sigma
Digital Supply(Max)(V)5.25
Digital Supply(Min)(V)2.7
Input Range(Max)(V)2.125
4.25
Input Range(Min)(V)-2.125
0
Input TypeDifferential
Single-Ended
Integrated Features50/60 Hz Rejection
Excitation Current Sources (iDACs)
GPIO
Oscillator
PGA
Temp Sensor
InterfaceSPI
Multi-Channel ConfigurationMultiplexed
Operating Temperature Range(C)-40 to 105
Package GroupTSSOP
Package Size: mm2:W x L (PKG)28TSSOP: 62 mm2: 6.4 x 9.7(TSSOP)
Power Consumption(Typ)(mW)2.3
RatingCatalog
Reference ModeExt
Int
Resolution(Bits)24
Sample Rate (max)(SPS)2kSPS

Packaging

Pin28
Package TypePW
Industry STD TermTSSOP
JEDEC CodeR-PDSO-G
Package QTY2000
CarrierLARGE T&R
Device MarkingADS1248
Width (mm)4.4
Length (mm)9.7
Thickness (mm)1
Pitch (mm).65
Max Height (mm)1.2
Mechanical DataDownload »

Manufacturer's Classification

Semiconductors > Data Converters > Analog to Digital Converter > Precision ADC (<=10MSPS)

Design Kits & Evaluation Modules

  • Evaluation Modules & Boards: ADS1248EVM-PDK
    ADS1248 Performance Demonstration Kit
    Lifecycle Status: Active (Recommended for new designs)

Application Notes

  • Download » Application Notes, PDF, 563 Kb, 03-13-2013
    RTD Ratiometric Measurements and Filtering Using the ADS1148 and ADS1248
    The ADS1148 and ADS1248 family of devices are highly integrated delta-sigma (О”ОЈ) converters that areoptimized for the measurement of temperature sensors, including resistance temperature detectors(RTDs), thermocouples, and thermistors. In a typical RTD measurement application, the ADS1148 andADS1248 are configured in a ratiometric topology using the built-in IDAC current sources feeding thro
  • Download » Application Notes, PDF, 178 Kb, Rev. B, 05-09-2016
    Example Temperature Measurement Applications Using the ADS1247 and ADS1248 (Rev. B)
    This document discusses the use of the ADS1247 and ADS1248 precision analog-to-digital converters (ADCs) together with a resistive temperature device (RTD) and thermocouple to measure temperature. Included are detailed examples of the most common configurations of a two-wire RTD, a three-wire RTD, a four-wire RTD, and a thermocouple with cold junction compensation. This document provides sufficien
  • Download » Application Notes, PDF, 127 Kb, 03-06-2003
    Inputs Currents for High-Resolution ADCs
  • Download » Application Notes, PDF, 69 Kb, Rev. A, 05-18-2015
    Analog-to-Digital Converter Grounding Practices Affect System Performance (Rev. A)
  • Download » Application Notes, PDF, 425 Kb, Rev. B, 10-09-2011
    A Glossary of Analog-to-Digital Specifications and Performance Characteristics (Rev. B)
    This glossary is a collection of the definitions of Texas Instruments' Delta-Sigma (О”ОЈ), successive approximation register (SAR), and pipeline analog-to-digital (A/D) converter specifications and performance characteristics. Although there is a considerable amount of detail in this document, the product data sheet for a particular product specification is the best and final reference.
  • Download » Application Notes, PDF, 64 Kb, 10-02-2000
    Interleaving Analog-to-Digital Converters
    It is tempting when pushing the limits of analog-to-digital conversion to consider interleaving two or more converters to increase the sample rate. However, such designs must take into consideration several possible sources of error.
  • Download » Application Notes, PDF, 132 Kb, Rev. A, 04-16-2015
    Principles of Data Acquisition and Conversion (Rev. A)
  • Download » Application Notes, PDF, 95 Kb, 10-02-2000
    What Designers Should Know About Data Converter Drift
    Exactly how inaccurate will a change in temperature make an analog-to-digital or digital-to-analog converter? As designers are well aware, a 12-bit device may provide a much lower accuracy at its operating-temperature extremes, perhaps only to 9 or even 8 bits. But for lack of more precise knowledge, many play it safe (and expensive) and overspecify.