Datasheet Texas Instruments TL594

ManufacturerTexas Instruments
SeriesTL594
Datasheet Texas Instruments TL594

Pulse-Width-Modulation (PWM) Control Circuit

Datasheets

TL594 Pulse-Width-Modulation Control Circuit datasheet
PDF, 1.4 Mb, Revision: I, File published: Sep 30, 2016
Extract from the document

Prices

Status

TL594CDTL594CDE4TL594CDG4TL594CDRTL594CDRG3TL594CDRG4TL594CNTL594CNE4TL594CNSRTL594CNSRG4TL594CPWTL594CPWRTL594CPWRG4TL594IDTL594IDG4TL594IDRTL594IDRG4TL594INTL594INE4TL594INSRTL594INSRG4TL594IPWRTL594IPWRG4
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Preview (Device has been announced but is not in production. Samples may or may not be available)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNoNo

Packaging

TL594CDTL594CDE4TL594CDG4TL594CDRTL594CDRG3TL594CDRG4TL594CNTL594CNE4TL594CNSRTL594CNSRG4TL594CPWTL594CPWRTL594CPWRG4TL594IDTL594IDG4TL594IDRTL594IDRG4TL594INTL594INE4TL594INSRTL594INSRG4TL594IPWRTL594IPWRG4
N1234567891011121314151617181920212223
Pin1616161616161616161616161616161616161616161616
Package TypeDDDDDDNNNSNSPWPWPWDDDDNNNSNSPWPW
Industry STD TermSOICSOICSOICSOICSOICSOICPDIPPDIPSOPSOPTSSOPTSSOPTSSOPSOICSOICSOICSOICPDIPPDIPSOPSOPTSSOPTSSOP
JEDEC CodeR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDIP-TR-PDIP-TR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDIP-TR-PDIP-TR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-G
Package QTY40404025002500252520002000902000200040402500250025252000200020002000
CarrierTUBETUBETUBELARGE T&RLARGE T&RTUBETUBELARGE T&RLARGE T&RTUBELARGE T&RLARGE T&RTUBETUBELARGE T&RLARGE T&RTUBETUBELARGE T&RLARGE T&RLARGE T&RLARGE T&R
Device MarkingTL594CTL594CTL594CTL594CTL594CTL594CTL594CNTL594CNTL594TL594T594T594T594TL594ITL594ITL594ITL594ITL594INTL594INTL594ITL594IZ594Z594
Width (mm)3.913.913.913.913.913.916.356.355.35.34.44.44.43.913.913.913.916.356.355.35.34.44.4
Length (mm)9.99.99.99.99.99.919.319.310.310.35559.99.99.99.919.319.310.310.355
Thickness (mm)1.581.581.581.581.581.583.93.91.951.951111.581.581.581.583.93.91.951.9511
Pitch (mm)1.271.271.271.271.271.272.542.541.271.27.65.65.651.271.271.271.272.542.541.271.27.65.65
Max Height (mm)1.751.751.751.751.751.755.085.08221.21.21.21.751.751.751.755.085.08221.21.2
Mechanical DataDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownloadDownload

Parametrics

Parameters / ModelsTL594CD
TL594CD
TL594CDE4
TL594CDE4
TL594CDG4
TL594CDG4
TL594CDR
TL594CDR
TL594CDRG3
TL594CDRG3
TL594CDRG4
TL594CDRG4
TL594CN
TL594CN
TL594CNE4
TL594CNE4
TL594CNSR
TL594CNSR
TL594CNSRG4
TL594CNSRG4
TL594CPW
TL594CPW
TL594CPWR
TL594CPWR
TL594CPWRG4
TL594CPWRG4
TL594ID
TL594ID
TL594IDG4
TL594IDG4
TL594IDR
TL594IDR
TL594IDRG4
TL594IDRG4
TL594IN
TL594IN
TL594INE4
TL594INE4
TL594INSR
TL594INSR
TL594INSRG4
TL594INSRG4
TL594IPWR
TL594IPWR
TL594IPWRG4
TL594IPWRG4
Approx. Price (US$)0.27 | 1ku
Control MethodVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltageVoltage
Duty Cycle(Max), %45454545454545454545454545454545454545454545
Duty Cycle(Max)(%)45
Frequency(Max), kHz300300300300300300300300300300300300300300300300300300300300300300
Frequency(Max)(kHz)300
Frequency(Min), kHz1111111111111111111111
Frequency(Min)(kHz)1
Gate Drive(Typ), A0.20.20.20.20.20.20.20.20.20.20.20.20.20.20.20.20.20.20.20.20.20.2
Gate Drive(Typ)(A)0.2
Operating Temperature Range, C-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70-40 to 85,0 to 70
Operating Temperature Range(C)-40 to 85
0 to 70
Package GroupSOICSOICSOICSOICSOICSOICPDIPPDIPSOSOTSSOPTSSOPTSSOPSOICSOICSOICSOICPDIPPDIPSOSOTSSOPTSSOP
RatingCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalogCatalog
Special FeaturesAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency
Error Amplifier
Multi-topology
Adjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topologyAdjustable Switching Frequency,Error Amplifier,Multi-topology
TopologyBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost
Buck
Flyback
Forward
Full-Bridge
Half-Bridge
Push-Pull
Boost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-PullBoost,Buck,Flyback,Forward,Full-Bridge,Half-Bridge,Push-Pull
UVLO Thresholds On/Off, V6.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/66.1/6
UVLO Thresholds On/Off(V)6.1/6
Vin(Max), V38383838383838383838383838383838383838383838
Vin(Max)(V)38
Vin(Min), V-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3-0.3
Vin(Min)(V)-0.3

Eco Plan

TL594CDTL594CDE4TL594CDG4TL594CDRTL594CDRG3TL594CDRG4TL594CNTL594CNE4TL594CNSRTL594CNSRG4TL594CPWTL594CPWRTL594CPWRG4TL594IDTL594IDG4TL594IDRTL594IDRG4TL594INTL594INE4TL594INSRTL594INSRG4TL594IPWRTL594IPWRG4
RoHSCompliantCompliantCompliantCompliantNot CompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliantCompliant
Pb FreeYesYesNoYesYes

Application Notes

  • Understanding Buck Power Stages In Switchmode Power Supplies
    PDF, 173 Kb, File published: Mar 4, 1999
    A switching power supply consists of the power stage and the control circuit. The power stage performs the basic power conversion from the input voltage to the output voltage and includes switches and the output filter. This report addresses the buck power stage only and does not cover control circuits. Detailed steady-state and small-signal analysis of the buck power stage operating in continuous
  • Understanding Boost Power Stages In Switchmode Power Supplies
    PDF, 149 Kb, File published: Mar 4, 1999
    A switching power supply consists of the power stage and the control circuit. The power stage performs the basic power conversion from the input voltage to the output voltage and includes switches and the output filter. This report addresses the boost power stage only and does not cover control circuits. The report includes detailed steady-stage and small-signal analysis of the boost power stage o
  • Understanding Buck-Boost Power Stages in Switchmode Power Supplies (Rev. A)
    PDF, 363 Kb, Revision: A, File published: May 28, 2002

Model Line

Manufacturer's Classification

  • Semiconductors> Power Management> Offline and Isolated DC/DC Controllers and Converters> PWM and Resonant Controller
EMS supplier