Datasheet Texas Instruments LM4140ACM-2.5/NOPB

ManufacturerTexas Instruments
SeriesLM4140
Part NumberLM4140ACM-2.5/NOPB
Datasheet Texas Instruments LM4140ACM-2.5/NOPB

Precision Micropower Low Dropout Voltage Reference 8-SOIC 0 to 70

Datasheets

LM4140 High Precision Low Noise Low Dropout Voltage Reference datasheet
PDF, 1.4 Mb, Revision: F, File published: Sep 16, 2016
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

Packaging

Pin88
Package TypeDD
Industry STD TermSOICSOIC
JEDEC CodeR-PDSO-GR-PDSO-G
Package QTY9595
CarrierTUBETUBE
Device MarkingCM2.54140A
Width (mm)3.913.91
Length (mm)4.94.9
Thickness (mm)1.581.58
Pitch (mm)1.271.27
Max Height (mm)1.751.75
Mechanical DataDownloadDownload

Parametrics

Initial Accuracy(Max)0.1 %
Iout/Iz(Max)8 mA
Iq(Max)320,375,350,400 uA
Iq(Typ)230,265 uA
LFN 0.1-10Hz(Typ)2.2 ОјVpp
Operating Temperature Range0 to 70 C
Package GroupSOIC
Package Size: mm2:W x L8SOIC: 29 mm2: 6 x 4.9(SOIC) PKG
Pin/Package8SOIC
RatingCatalog
Shutdown Current(Typ)0.1 uA
Special FeaturesEnable pin
Temp Coeff(Max)3,6,10 ppm/ degree C
VO1.024,1.25,2.048,2.5,4.096 V
Vin(Max)5.5 V
Vin(Min)1.8 V

Eco Plan

RoHSCompliant

Design Kits & Evaluation Modules

  • Evaluation Modules & Boards: LMP91051EVM
    LMP91051 Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)
  • Evaluation Modules & Boards: DDC2256AEVM
    DDC2256A Evaluation Module for 256-channel Current-input Analog-to-digital Converter
    Lifecycle Status: Active (Recommended for new designs)

Application Notes

  • AN-1559 Practical RTD Interface Solutions (Rev. B)
    PDF, 120 Kb, Revision: B, File published: May 1, 2013
    This application report is intended to review Resistance Temperature Devices (RTD) and commonly usedinterfaces for them.
  • AN-1852 Designing With pH Electrodes (Rev. A)
    PDF, 115 Kb, Revision: A, File published: May 1, 2013
    A pH electrode measures hydrogen ion (H+) activity and produces an electrical potential or voltage. Theoperation of the pH electrode is based on the principle that an electric potential develops when two liquidsof different pH come into contact at opposite sides of a thin glass membrane. This was originallydiscovered in 1906 by Max Cremer [1]. His discovery laid the foundation for Fritz Habe
  • Improving Machinery Vibration Analysis
    PDF, 522 Kb, File published: Jul 7, 2006

Model Line

Manufacturer's Classification

  • Semiconductors > Power Management > Voltage Reference > Series Voltage Reference

Other Names:

LM4140ACM2.5/NOPB, LM4140ACM 2.5/NOPB