Datasheet Texas Instruments SN65HVD08D

ManufacturerTexas Instruments
SeriesSN65HVD08
Part NumberSN65HVD08D
Datasheet Texas Instruments SN65HVD08D

3.3/5-V RS-485 Transceiver 8-SOIC -40 to 85

Datasheets

SNx5HVD08 Wide Supply Range RS-485 Transceiver datasheet
PDF, 988 Kb, Revision: D, File published: Jul 9, 2015
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

Packaging

Pin8
Package TypeD
Industry STD TermSOIC
JEDEC CodeR-PDSO-G
Package QTY75
CarrierTUBE
Device MarkingVP08
Width (mm)3.91
Length (mm)4.9
Thickness (mm)1.58
Pitch (mm)1.27
Max Height (mm)1.75
Mechanical DataDownload

Parametrics

Common Mode Range-7 to 12
DuplexHalf
Fail SafeIdle,Open,Short
Fault Protection-9 to 14 V
HBM ESD16 kV
ICC(Max)16 mA
IEC 61000-4-2 ContactN/A +/- kV
IsolatedNo
No. of RX1
No. of TX1
Number of Nodes256
Operating Temperature Range-40 to 85 C
Package GroupSOIC
RatingCatalog
Signaling Rate(Max)10 Mbps
Supply Voltage(s)(Nom)3.3, 5 V

Eco Plan

RoHSCompliant

Design Kits & Evaluation Modules

  • Evaluation Modules & Boards: RS485-HF-DPLX-EVM
    RS-485 Half-Duplex Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

Application Notes

  • RS-485 for Digital Motor Control Applications
    PDF, 180 Kb, File published: May 12, 2003
    This application report focuses on the benefits of using RS-485 signaling for motor control and motion control applications. This technology has several benefits for these applications in terms of noise immunity, wide common-mode voltage range, adequate data rate, and multipoint capability. Other applications also use RS-485 signaling to take advantage of these same benefits. Applications such as
  • The RS-485 Unit Load and Maximum Number of Bus Connections
    PDF, 197 Kb, File published: Mar 15, 2004
    The TIA/EIA-485 (RS-485) standard defines a Unit Load and confines bus configurations to 32. This report explains the Unit-Load concept and how it relates to the maximum number of bus connections. Fractional Unit-Load devices, such at the 1/8th Unit-Load SN65HVD21 and SN65HVD06, allow up to 256 devices on a single bus segment.

Model Line

Manufacturer's Classification