Datasheet Texas Instruments ADS1299IPAG

ManufacturerTexas Instruments
SeriesADS1299
Part NumberADS1299IPAG
Datasheet Texas Instruments ADS1299IPAG

Low-Noise, 8-Channel, 24-Bit Analog-to-Digital Converter for Biopotential Measurements 64-TQFP -40 to 85

Datasheets

ADS1299-x Low-Noise, 4-, 6-, 8-Channel, 24-Bit, Analog-to-Digital Converter for EEG and Biopotential Measurements datasheet
PDF, 2.1 Mb, Revision: C, File published: Jan 25, 2017
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Packaging

Pin64
Package TypePAG
Industry STD TermTQFP
JEDEC CodeS-PQFP-G
Package QTY160
CarrierTUBE
Device MarkingADS1299
Width (mm)10
Length (mm)10
Thickness (mm)1
Pitch (mm).5
Max Height (mm)1.2
Mechanical DataDownload

Parametrics

# Input Channels8
Analog Voltage AVDD(Max)5.25 V
Analog Voltage AVDD(Min)4.75 V
ArchitectureDelta-Sigma
Digital Supply(Max)3.6 V
Digital Supply(Min)1.8 V
Input Range(Max)5.25 V
Input TypeDifferential
Integrated FeaturesDaisy-Chainable,GPIO,Oscillator,PGA
InterfaceSPI
Multi-Channel ConfigurationSimultaneous Sampling
Operating Temperature Range-40 to 85 C
Package GroupTQFP
Package Size: mm2:W x L64TQFP: 144 mm2: 12 x 12(TQFP) PKG
Power Consumption(Typ)41 mW
RatingCatalog
Reference ModeExt,Int
Resolution24 Bits
SNR121 dB
Sample Rate (max)16KSPS SPS
Sample Rate(Max)0.016 MSPS
THD(Typ)-99 dB

Eco Plan

RoHSCompliant

Design Kits & Evaluation Modules

  • Evaluation Modules & Boards: ADS1299EEGFE-PDK
    ADS1299 Performance Demonstration Kit
    Lifecycle Status: Active (Recommended for new designs)

Application Notes

  • Improving Common-Mode Rejection Using the Right-Leg Drive Amplifier
    PDF, 297 Kb, File published: Jul 6, 2011
    This article discusses the need to improve common-mode rejection (CMR) in electrocardiogram (ECG) subsystem applications. Several different techniques to improve CMR while also considering both patient and operator safety are presented. This report also reviews the implementation of the right-leg drive (RLD) loop technique to improve CMR using the ADS129x family of analog-to-digital converters (in
  • Digital Filter Types in Delta-Sigma ADCs
    PDF, 219 Kb, File published: Jun 27, 2017
    This application report discusses digital filters which are a ubiquitous feature in delta-sigma analog todigital converters (ADCs). Digital low-pass filters are essential to the functionality of a delta-sigma ADCwhich relies on oversampling and noise shaping to push quantization noise out of band. There arevariations between the types of digital filters used in delta-sigma ADCs that provide
  • Analog-to-Digital Converter Grounding Practices Affect System Performance (Rev. A)
    PDF, 69 Kb, Revision: A, File published: May 18, 2015
  • A Glossary of Analog-to-Digital Specifications and Performance Characteristics (Rev. B)
    PDF, 425 Kb, Revision: B, File published: Oct 9, 2011
    This glossary is a collection of the definitions of Texas Instruments' Delta-Sigma (О”ОЈ), successive approximation register (SAR), and pipeline analog-to-digital (A/D) converter specifications and performance characteristics. Although there is a considerable amount of detail in this document, the product data sheet for a particular product specification is the best and final reference.
  • Principles of Data Acquisition and Conversion (Rev. A)
    PDF, 132 Kb, Revision: A, File published: Apr 16, 2015

Model Line

Series: ADS1299 (2)

Manufacturer's Classification

  • Semiconductors > Data Converters > Analog-to-Digital Converters (ADCs) > Precision ADCs (<=10MSPS)