Datasheet Texas Instruments ISO1050DUBR
Manufacturer | Texas Instruments |
Series | ISO1050 |
Part Number | ISO1050DUBR |
Isolated 5 V CAN Transceiver 8-SOP -55 to 105
Datasheets
ISO1050 Isolated CAN Transceiver datasheet
PDF, 2.0 Mb, Revision: I, File published: Jan 22, 2015
Extract from the document
Prices
Status
Lifecycle Status | Active (Recommended for new designs) |
Manufacture's Sample Availability | Yes |
Packaging
Pin | 8 |
Package Type | DUB |
Industry STD Term | SOP |
JEDEC Code | R-PDSO-G |
Package QTY | 350 |
Carrier | LARGE T&R |
Device Marking | ISO1050 |
Width (mm) | 6.57 |
Length (mm) | 9.5 |
Thickness (mm) | 3.3 |
Pitch (mm) | 2.54 |
Max Height (mm) | 4.85 |
Mechanical Data | Download |
Parametrics
CSA 60601-1 Reinforced Working | 125 Vrms |
CSA 60950-1 Basic Working | 760,730 Vrms |
CSA 60950-1 Reinforced Working | 380,148 Vrms |
CSA 61010-1 Basic Working | 600 Vrms |
CSA 61010-1 Reinforced Working | 300,148 Vrms |
CSA Isolation Rating | 5000,2500 Vrms |
DIN V VDE V 0884-10 Working Voltage | 1.2 Vpk |
DIN V VDE V 0884-10 Transient Overvoltage Rating | 4 Vpk |
Datarate | 1 Mbps |
Fault Protection | -27 to 40 V |
Isolation Rating | 4.2 Vrms |
Operating Temperature Range | -55 to 105 C |
Package Group | SOP |
Package Size: mm2:W x L | 8SOP: 62 mm2: 6.57 x 9.5(SOP) PKG |
Surge Voltage Rating | 4 Vpk |
TUV EN 60950-1 Basic Working | 400 Vrms |
TUV EN 60950-1 Reinforced Working | 600 Vrms |
TUV EN 61010-1 Basic Working | 400 Vrms |
TUV EN 61010-1 Reinforced Working | 600 Vrms |
TUV Isolation Rating | 5000,2500 Vrms |
UL 1577 Isolation Voltage (Double) | 3.5,2.5 Vrms |
VCC1(Max) | 5.5 V |
VCC1(Min) | 3 V |
VCC2(Max) | 5.25 V |
VCC2(Min) | 4.75 V |
Eco Plan
RoHS | Compliant |
Design Kits & Evaluation Modules
- Evaluation Modules & Boards: ISO1050EVM
ISO1050 Isolated CAN Transceiver Evaluation Module
Lifecycle Status: Active (Recommended for new designs) - Development Kits: TMDXIDDK379D
C2000 DesignDRIVE Development Kit for Industrial Motor Control
Lifecycle Status: Active (Recommended for new designs) - Evaluation Modules & Boards: EVMK2G
66AK2Gx (K2G) Evaluation Module
Lifecycle Status: Active (Recommended for new designs)
Application Notes
- Isolated CAN Reference Design (Rev. C)PDF, 39 Kb, Revision: C, File published: Sep 14, 2018
This design note presents the reference design of an isolated CAN node using the isolated CAN transceiver and a transformer driver SN6505A to generate the isolated power. - Isolated CAN solution by using ISO1050 and SN6501PDF, 406 Kb, File published: Jan 16, 2013
- Common-Mode Chokes in CAN Networks: Source of Unexpected TransientsPDF, 230 Kb, File published: Jan 29, 2008
Common-mode chokes are frequently used in automotive CAN networks to increase system reliability with respect to electromagnetic compatibility (EMC). Electromagnetic interference emitted from an Electronic Control Module (ECU) through the CAN transceiver can be filtered, thus limiting unwanted high-frequency noise on the communication bus. Another reason for using a common-mode choke is attempting
Model Line
Series: ISO1050 (4)
- ISO1050DUB ISO1050DUBR ISO1050DW ISO1050DWR
Manufacturer's Classification
- Semiconductors > Isolation > Isolated CAN Transceivers