Datasheet Texas Instruments SN65HVD21

ManufacturerTexas Instruments
SeriesSN65HVD21
Datasheet Texas Instruments SN65HVD21

Extended Common-mode RS-485 Transceiver

Datasheets

SN65HVD2x Extended Common-Mode RS-485 Transceivers datasheet
PDF, 1.3 Mb, Revision: F, File published: Nov 18, 2016
Extract from the document

Prices

Status

SN65HVD21DSN65HVD21DG4SN65HVD21DRSN65HVD21DRG4SN65HVD21PSN65HVD21PE4
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityNoNoNoYesYesNo

Packaging

SN65HVD21DSN65HVD21DG4SN65HVD21DRSN65HVD21DRG4SN65HVD21PSN65HVD21PE4
N123456
Pin888888
Package TypeDDDDPP
Industry STD TermSOICSOICSOICSOICPDIPPDIP
JEDEC CodeR-PDSO-GR-PDSO-GR-PDSO-GR-PDSO-GR-PDIP-TR-PDIP-T
Package QTY7575250025005050
CarrierTUBETUBELARGE T&RLARGE T&RTUBETUBE
Device MarkingVP21VP21VP21VP2165HVD2165HVD21
Width (mm)3.913.913.913.916.356.35
Length (mm)4.94.94.94.99.819.81
Thickness (mm)1.581.581.581.583.93.9
Pitch (mm)1.271.271.271.272.542.54
Max Height (mm)1.751.751.751.755.085.08
Mechanical DataDownloadDownloadDownloadDownloadDownloadDownload

Parametrics

Parameters / ModelsSN65HVD21D
SN65HVD21D
SN65HVD21DG4
SN65HVD21DG4
SN65HVD21DR
SN65HVD21DR
SN65HVD21DRG4
SN65HVD21DRG4
SN65HVD21P
SN65HVD21P
SN65HVD21PE4
SN65HVD21PE4
Common Mode Range-20 to 25-20 to 25-20 to 25-20 to 25-20 to 25-20 to 25
DuplexHalfHalfHalfHalfHalfHalf
Fail SafeIdle,Open,ShortIdle,Open,ShortIdle,Open,ShortIdle,Open,ShortIdle,Open,ShortIdle,Open,Short
Fault Protection, V-27 to 27-27 to 27-27 to 27-27 to 27-27 to 27-27 to 27
HBM ESD, kV161616161616
ICC(Max), mA121212121212
IEC 61000-4-2 Contact, +/- kVN/AN/AN/AN/AN/AN/A
IsolatedNoNoNoNoNoNo
No. of RX111111
No. of TX111111
Number of Nodes256256256256256256
Operating Temperature Range, C-40 to 85-40 to 85-40 to 85-40 to 85-40 to 85-40 to 85
Package GroupSOICSOICSOICSOICPDIPPDIP
RatingCatalogCatalogCatalogCatalogCatalogCatalog
Signaling Rate(Max), Mbps555555
Supply Voltage(s)(Nom), V555555

Eco Plan

SN65HVD21DSN65HVD21DG4SN65HVD21DRSN65HVD21DRG4SN65HVD21PSN65HVD21PE4
RoHSCompliantCompliantCompliantCompliantCompliantCompliant
Pb FreeYesYes

Application Notes

  • The RS-485 Unit Load and Maximum Number of Bus Connections
    PDF, 197 Kb, File published: Mar 15, 2004
    The TIA/EIA-485 (RS-485) standard defines a Unit Load and confines bus configurations to 32. This report explains the Unit-Load concept and how it relates to the maximum number of bus connections. Fractional Unit-Load devices, such at the 1/8th Unit-Load SN65HVD21 and SN65HVD06, allow up to 256 devices on a single bus segment.

Model Line

Manufacturer's Classification

  • Semiconductors> Interface> RS-485 Transceivers