AD589–SPECIFICATIONS (Typical @ IIN = 500 A and TA = 25 C, unless otherwise noted.)AD589JH/ModelAD589JRAD589KHAD589LHAD589MHMin Typ Max Min Typ Max Min Typ Max Min Typ Max Unit OUTPUT VOLTAGE, TA = 25°C 1.200 1.235 1.2501.200 1.235 1.2501.200 1.235 1.2501.200 1.235 1.250 V OUTPUT VOLTAGE CHANGE VERSUS CURRENT 50 A to 5 mA 5 5 5 5 mV DYNAMIC OUTPUT IMPEDANCE 0.6 2 0.6 2 0.6 2 0.6 2 RMS NOISE VOLTAGE 10 Hz < f < 10 kHz 5 5 5 5 V TEMPERATURE COEFFICIENT1 100 50 25 10 ppm/°C TURN-ON SETTLING TIME TO 0.1% 25 25 25 25 s OPERATING CURRENT2 0.05 5 0.05 5 0.05 5 0.05 5 mA OPERATING TEMPERATURE 0 70 0 70 0 70 0 70 °C PACKAGE OPTION3 Metal Can (H-02A) AD589JH AD589KH AD589LH AD589MH SOIC (R-8) AD589JR Model AD589SHAD589THMin Typ Max Min Typ Max Unit OUTPUT VOLTAGE, TA = 25°C 1.200 1.235 1.2501.200 1.235 1.250 V OUTPUT VOLTAGE CHANGE VERSUS CURRENT 50 A to 5 mA 5 5 mV DYNAMIC OUTPUT IMPEDANCE 0.6 2 0.6 2 RMS NOISE VOLTAGE 10 Hz < f < 10 kHz 5 5 V TEMPERATURE COEFFICIENT1 10050 ppm/°C TURN-ON SETTLING TIME TO 0.1% 25 25 s OPERATING CURRENT2 0.05 5 0.05 5 mA OPERATING TEMPERATURE –55 +125 –55 +125 °C PACKAGE OPTION3 Metal Can (H-02) AD589SH AD589TH SOIC (R-8) AD589JR NOTES 1See the Voltage Variation versus Temperature section for explanation of temperature coeffi cient measurement method. 2Optimum performance is obtained at currents below 500 A. For current operation below 200 A, stray shunt capacitances should be limited to 20 pF or increased to 1 F. If strays cannot be avoided, operation at 500 A and a shunt capacitor of at least 1000 pF are recommended. 3H = Hermetic Metal Can; R = SOIC. Specifi cations shown in boldface are tested on all production units at fi nal electrical test. Specifi cations subject to change without notice. –2– REV. C Document Outline FEATURES PRODUCT DESCRIPTION FUNCTIONAL BLOCK DIAGRAMS PRODUCT HIGHLIGHTS SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS AD589 CHIP DIMENSIONS AND PAD LAYOUT ORDERING GUIDE UNDERSTANDING THE SPECIFICATIONS Voltage Variation Versus Temperature Dynamic Performance APPLICATION INFORMATION OUTLINE DIMENSIONS Revision History