Datasheet LT1776 (Analog Devices) - 3

ManufacturerAnalog Devices
DescriptionWide Input Range, High Efficiency, Step-Down Switching Regulator
Pages / Page20 / 3 — ELECTRICAL CHARACTERISTICS. The
File Format / SizePDF / 235 Kb
Document LanguageEnglish

ELECTRICAL CHARACTERISTICS. The

ELECTRICAL CHARACTERISTICS The

Model Line for this Datasheet

Text Version of Document

LT1776
ELECTRICAL CHARACTERISTICS The

denotes specifications which apply over the full operating temperature range, otherwise specifications are TA = 25
°
C. VIN = 40V, VSW open, VCC = 5V, VC = 1.4V unless otherwise noted. SYMBOL PARAMETER CONDITIONS MIN TYP MAX UNITS Timing
f Switching Frequency 180 200 220 kHz ● 170 230 kHz Maximum Switch Duty Cycle ● 85 90 % tON(MIN) Minimum Switch On Time High dV/dt Mode, RL = 39Ω (Note 4) 300 ns
Boost Operation
VC Pin Boost Threshold 1.35 V dV/dt Below Threshold 0.2 V/ns dV/dt Above Threshold 1.6 V/ns
Sync Function
Minimum Sync Amplitude ● 1.5 2.2 V Synchronization Range (Note 6) ● 250 400 kHz SYNC Pin Input R 40 kΩ
SHDN Pin Function
VSHDN Shutdown Mode Threshold 0.5 V ● 0.2 0.8 V Upper Lockout Threshold Switching Action On 1.260 V Lower Lockout Threshold Switching Action Off 1.245 V ISHDN Shutdown Pin Current VSHDN = 0V 12 20 µA VSHDN = 1.25V 2.5 10 µA
Note 1:
Absolute Maximum Ratings are those values beyond which the life
Note 5:
Parts are guaranteed to survive 60V on VIN and VSW. However, of a device may be impaired. thermal constraints will limit VIN in some applications, depending primarily
Note 2:
Control circuitry powered from V on maximum output current and switching frequency. See Applications CC.
Note 3:
Switch current limit is DC trimmed and tested in production. section for more information. Inductor dl/dt rate will cause a somewhat higher current limit in actual
Note 6:
Internal oscillator is guaranteed to sync up to 400kHz. However, application. thermal constraints and/or controllability issues may place a lower limit on
Note 4:
Minimum switch on time is production tested with a 39Ω resistive switching frequency in actual usage. See Applications section for more load to ground. information. 3