Datasheet X9312 (Intersil) - 5

ManufacturerIntersil
DescriptionDigitally Controlled Potentiometer (XDCP)
Pages / Page9 / 5 — X9312. D.C. OPERATING CHARACTERISTICS. Limits. Symbol. Parameter. Min. …
File Format / SizePDF / 247 Kb
Document LanguageEnglish

X9312. D.C. OPERATING CHARACTERISTICS. Limits. Symbol. Parameter. Min. Typ.(4). Max. Unit. Test Conditions. ENDURANCE AND DATA RETENTION

X9312 D.C OPERATING CHARACTERISTICS Limits Symbol Parameter Min Typ.(4) Max Unit Test Conditions ENDURANCE AND DATA RETENTION

Model Line for this Datasheet

Text Version of Document

X9312 D.C. OPERATING CHARACTERISTICS
(Over recommended operating conditions unless otherwise specified.)
Limits Symbol Parameter Min. Typ.(4) Max. Unit Test Conditions
ICC VCC active current (Increment) 1 3 mA CS = VIL, U/D = VIL or VIH and INC = 0.4V/2.4V @ max. tCYC ISB Standby supply current 500 1000 µA CS = VCC - 0.3V, U/D and INC = VSS or VCC - 0.3V ILI CS, INC, U/D input leakage current ±10 µA VIN = VSS to VCC VIH CS, INC, U/D input HIGH voltage 2 VCC + 1 V VIL CS, INC, U/D input LOW voltage -1 0.8 V C (5) IN CS, INC, U/D input capacitance 10 pF VCC = 5V, VIN = VSS, TA = 25°C, f = 1MHz
ENDURANCE AND DATA RETENTION Parameter Min. Unit
Minimum endurance 100,000 Data changes per bit Data retention 100 Years Notes: (4) Typical values are for TA = 25°C and nominal supply voltage. (5) This parameter is periodically sampled and not 100% tested.
Test Circuit #1 Test Circuit #2 Circuit #3 SPICE Macro Model
V V H/RH H/RH RTOTAL Test Point RH RL CL CW V CH S Test Point VW V 10pF W/RW VW/RW Force 25pF Current 10pF V L VL/RL L/RL RW
A.C. CONDITIONS OF TEST
Input pulse levels 0V to 3V Input rise and fall times 10ns Input reference levels 1.5V 5 FN8176.0 March 15, 2005