AD7792/AD7793Key SheetSingle Conversion ModeCS In single conversion mode, the AD7792/AD7793 perform a single conversion and are placed in standby mode after the DATAREQUEST conversion is complete. DOUT/RDY goes low to indicate the DIN completion of a conversion. When the data-word has been read DATA from the data register, DOUT/RDY goes high. The data register DOUT/RDY can be read several times, if required, even when DOUT/RDY has gone high. 004 SCLK 11263- Figure 5. Single Conversion Mode TYPICAL APPLICATION DIAGRAMGNDAVDDVBIASREFIN(+) REFIN(–)THERMOCOUPLEBAND GAPJUNCTION RREFERENCEAIN1(+)GNDAIN1(–)AVDDR CDOUT/RDYMUXAIN2(+)SERIALINTERFACEDINΣ-ΔAIN2(–)BUFIN-AMPANDADCSCLKCONTROLLOGICCSREFIN(+)RREFGNDDVDDINTERNALREFIN(–)AVDDCLOCKIOUT2AD7792/AD7793 007 CLK 11263- Figure 6. Typical Application Diagram for Thermocouple Measurement Rev. 0 | Page 4 of 6 Document Outline General Description Features and Benefits Key Characteristics Fundamental Specifications Noise Operating the AD7792/AD7793 Data Interface Data Modes Continuous Conversion Mode (Default) Continuous Read Mode Single Conversion Mode Typical Application Diagram Frequently Asked Questions Learn More and Start Designing Compatible Devices Package Diagram Getting Started