Datasheet RV1S9353A (Renesas) - 4

ManufacturerRenesas
DescriptionOptically Isolated Delta-Sigma Modulator
Pages / Page20 / 4 — RV1S9353A. Chapter. Title. ABSOLUTE. MAXIMUM. RATINGS. (TA. =. 25C,. …
File Format / SizePDF / 1.8 Mb
Document LanguageEnglish

RV1S9353A. Chapter. Title. ABSOLUTE. MAXIMUM. RATINGS. (TA. =. 25C,. unless. otherwise. specified). Parameter. Symbol. Ratings. Unit. Operating. Ambient

RV1S9353A Chapter Title ABSOLUTE MAXIMUM RATINGS (TA = 25C, unless otherwise specified) Parameter Symbol Ratings Unit Operating Ambient

Model Line for this Datasheet

Text Version of Document

RV1S9353A Chapter Title ABSOLUTE MAXIMUM RATINGS (TA = 25C, unless otherwise specified) Parameter Symbol Ratings Unit Operating Ambient Temperature TA 40 to 110 C Storage Temperature Tstg 55 to 150 C Supply Voltage VDD1, VDD2 6 V Input Voltage*1 VIN, VIN 2 to VDD1 0.5 V Input Voltage*1,2 VIN, VIN 6 to VDD1 0.5 V Output Voltage MCLK, MDAT 6 V Isolation Voltage*3 BV 5 000 Vr.m.s. *1 The input voltage of Vin+ and Vin- terminals is less than 6V. *2 Duration of time is within 2 seconds. *3 AC voltage for 1 minute at TA = 25C, RH = 60% between input and output. Pins 1-4 shorted together, 5-8 shorted together. RECOMMENDED OPERATING CONDITIONS Parameter Symbol MIN. TYP. MAX. Unit Operating Ambient Temperature TA 40 110 C Supply Voltage VDD1 VDD1 4.5 5 5.5 V Supply Voltage VDD2 VDD2 3.0 5.5 V Input Voltage (Accurate and Linear) *1 VIN, VIN 200 200 mV *1 Using VIN = 0 V (to be connected to GND1) is recommended. Avoid using VIN of 2.5 V or more, because the internal test mode is activated when the voltage VIN reaches more than 2.5 V. R08DS0174EJ0100 Rev.1.00 Page 4 of 19 Mar 23, 2020