Datasheet AD628 (Analog Devices) - 6

ManufacturerAnalog Devices
DescriptionHigh Common-Mode Voltage, Programmable Gain Difference Amplifier
Pages / Page20 / 6 — AD628. AD628AR. AD628ARM. Parameter. Conditions. Min Typ Max Min Typ Max …
RevisionG
File Format / SizePDF / 361 Kb
Document LanguageEnglish

AD628. AD628AR. AD628ARM. Parameter. Conditions. Min Typ Max Min Typ Max Unit

AD628 AD628AR AD628ARM Parameter Conditions Min Typ Max Min Typ Max Unit

Model Line for this Datasheet

Text Version of Document

link to page 16
AD628 AD628AR AD628ARM Parameter Conditions Min Typ Max Min Typ Max Unit
POWER SUPPLY Operating Range ±2.25 +36 ±2.25 +36 V Quiescent Current 1.6 1.6 mA TEMPERATURE RANGE −40 +85 −40 +85 °C 1 To use a lower gain, see the Gain Adjustment section. 2 The addition of the difference amplifier and output amplifier offset voltage does not exceed this specification. ⎡ ⎤ ⎢(0.1)(V ) ⎥ 3 Error due to common mode as seen at the output: CM V = ×[Output Amplifier ] Gain OUT ⎢ . 75 ⎥ ⎢ ⎥ ⎣ 10 20 ⎦ 4 Greater values of voltage are possible with greater or lesser values of VREF. ⎡ ⎤ ⎢(0.1)(V ) CM ⎥ 5 Error due to common mode as seen at the output of A1: V A1 = OUT ⎢ . 75 ⎥ ⎢ ⎥ ⎣ 20 10 ⎦ Rev. G | Page 6 of 20 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS THERMAL CHARACTERISTICS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS TEST CIRCUITS THEORY OF OPERATION APPLICATIONS INFORMATION GAIN ADJUSTMENT INPUT VOLTAGE RANGE VOLTAGE LEVEL CONVERSION CURRENT LOOP RECEIVER MONITORING BATTERY VOLTAGES FILTER CAPACITOR VALUES KELVIN CONNECTION OUTLINE DIMENSIONS ORDERING GUIDE