Datasheet AOZ7270DI (Alpha & Omega) - 9

ManufacturerAlpha & Omega
Description600V "Zero Bridge Loss" AlphaZBL Ideal Diode
Pages / Page17 / 9 — AOZ7270DI. Surge Test. Note:. Inrush Current Test. Figure 14. First Time …
File Format / SizePDF / 1.1 Mb
Document LanguageEnglish

AOZ7270DI. Surge Test. Note:. Inrush Current Test. Figure 14. First Time Power On. Figure 15. 10k Times Power On. www.aosmd.com

AOZ7270DI Surge Test Note: Inrush Current Test Figure 14 First Time Power On Figure 15 10k Times Power On www.aosmd.com

Model Line for this Datasheet

Text Version of Document

AOZ7270DI Surge Test
Test conditions: 230V/50Hz Input with 60W EMI filter without NTCR Common mode lighting surge(L-FG; N-FG):Pass 4kV(2) Differential mode lighting surge (L-N):Pass 2.5kV*
Note:
2. X-Cap of EMI boardbroken at the 3kV DM lighting surge, so we don’t keep to test at 3kV level. Even X-Cap Broken by the 3kV DM surge, Alpha- ZBL still in work without fail.
Inrush Current Test
Without NTCR, EMI filter, TVS and varistor. Output capacitor is 120µF. Peak current > 1.2kApeak.
Figure 14. First Time Power On Figure 15. 10k Times Power On
Rev. 1.0 September 2020
www.aosmd.com
Page 9 of 17