InnoSwitch5-ProPI COMMAND Register Address Assignments, Description and Control Range Al command register addresses in InnoSwitch5-Pro are odd-parity addressing. Some select registers (some highlighted below) also employ odd parity error bit to the high and low bytes of data. Register AddressNameFunctionAdjustmentAddressRangeTypeDefaultDescriptionAddress with OddParity bit[7] Parity VBEN Series Bus Enable or {11} Enable VBEN/Disable VDIS Switch Control Disabled? 0x04 W_Byte 0x0 bit[1:0] {01} Disable VBEN/No Reset {00} Disable VBEN/Reset {0}: Auto disable when bit[2] VOUT<10PCT {1}: Auto disable when Activate VOUT<4PCT BLEEDER Enable or B Bleeder (V ) OUT Function Disabled? 0x06 0x86 W_Byte 0xD0 {00}: Disabled bit[1:0] {11}: Enabled with auto disable OTP clears this register bit[7] Parity {0011} Enable Discharge/ VDIS Load (VBUS) Enable or Disable VBEN/Reset Discharge Disabled? 0x08 W_Byte 0x0 bit[3:0] {0010} Enable Discharge/ Disable VBEN No Reset {1110} Disable Discharge Turn-Off Latch-Off Enable or PSU Device Disabled? 0x0A 0x8A W_Byte 0x0 bit[0] {0}: Disabled {1}: Enabled Fast VI Speed of CV/CC 10 ms Update Command Update Limit or 0x0C 0x8C W_Byte 0x0 bit[0] {1}: Disable 10 msec update No Speed Limit? limit {11}: 64 ms bit[4:3] {10}: 32 ms {01}: 16 ms {00}: 8 ms {11}: Disable-OutputA CVO Constant- Voltage Only Only CV Mode 0x0E W_Byte 0x04 bit[2:1] {10}: Auto-Restart {01}: Latch-Off {00}: No Response bit[0] {1}: CV Only Mode/No CC Regulation bit[15] High Byte Parity Range CV Output Voltage 3 V to 30 V bit[12:8] Output Voltage (10 mV/step) 0x10 W_Word 500 (5 V) {300 to 3000} bit[7] Low Byte Parity 10 mV/LSB bit[6:0] Output Voltage Table 2. Command Register Assignments. 10 Rev. C 01/24 www.power.com