Datasheet Texas Instruments THS6182DWPR
Manufacturer | Texas Instruments |
Series | THS6182 |
Part Number | THS6182DWPR |
Low Power Dissipation ADSL Line Driver 20-SO PowerPAD -40 to 85
Datasheets
Low Power Dissipation ADSL Line Driver datasheet
PDF, 1.8 Mb, Revision: H, File published: Jun 11, 2007
Extract from the document
Prices
Status
Lifecycle Status | Active (Recommended for new designs) |
Manufacture's Sample Availability | No |
Packaging
Pin | 20 |
Package Type | DWP |
Industry STD Term | HSOIC |
JEDEC Code | R-PDSO-G |
Package QTY | 2000 |
Carrier | LARGE T&R |
Device Marking | THS6182 |
Width (mm) | 7.52 |
Length (mm) | 12.82 |
Thickness (mm) | 2.55 |
Pitch (mm) | 1.27 |
Max Height (mm) | 2.65 |
Mechanical Data | Download |
Parametrics
2nd Harmonic | 88 dBc |
3rd Harmonic | 107 dBc |
@ MHz | 1 |
Acl, min spec gain | 1 V/V |
Additional Features | N/A |
Architecture | Current FB |
BW @ Acl | 100 MHz |
CMRR(Min) | 48 dB |
CMRR(Typ) | 54 dB |
GBW(Typ) | 100 MHz |
Input Bias Current(Max) | 15000000 pA |
Iq per channel(Max) | 12.5 mA |
Iq per channel(Typ) | 11.5 mA |
Number of Channels | 2 |
Offset Drift(Typ) | 50 uV/C |
Operating Temperature Range | -40 to 85 C |
Output Current(Typ) | 600 mA |
Package Group | SO PowerPAD |
Package Size: mm2:W x L | 20SO PowerPAD: 133 mm2: 10.405 x 12.825(SO PowerPAD) PKG |
Rail-to-Rail | No |
Rating | Catalog |
Slew Rate(Typ) | 450 V/us |
Total Supply Voltage(Max) | 33 +5V=5, +/-5V=10 |
Total Supply Voltage(Min) | 8 +5V=5, +/-5V=10 |
Vn at 1kHz(Typ) | 13 nV/rtHz |
Vn at Flatband(Typ) | 3.2 nV/rtHz |
Vos (Offset Voltage @ 25C)(Max) | 20 mV |
Eco Plan
RoHS | Compliant |
Design Kits & Evaluation Modules
- Evaluation Modules & Boards: THS6182RHFEVM
THS6182RHF Evaluation Module
Lifecycle Status: Active (Recommended for new designs) - Evaluation Modules & Boards: THS6182DWEVM
THS6182DW Evaluation Module
Lifecycle Status: Active (Recommended for new designs)
Application Notes
- Wireline Data Transmission and ReceptionPDF, 191 Kb, File published: Jan 27, 2010
Many types of wires are widely used to transmit data. Specifically, Category 3 and Category 5 (Cat3 and Cat5e, respectively)—also known as unshielded twisted pair or UTP lines—are now recommended for new telephone installations. Coaxial (coax) cables are used to distribute cable television (CATV) signals throughout a home. #12 and #14 American wire gauge (AWG) electric power distribution wire is a - Noise Analysis for High Speed Op Amps (Rev. A)PDF, 256 Kb, Revision: A, File published: Jan 17, 2005
As system bandwidths have increased an accurate estimate of the noise contribution for each element in the signal channel has become increasingly important. Many designers are not however particularly comfortable with the calculations required to predict the total noise for an op amp or in the conversions between the different descriptions of noise. Considerable inconsistency between manufactu
Model Line
Series: THS6182 (7)
- THS6182D THS6182DW THS6182DWP THS6182DWPR THS6182DWPRG4 THS6182RHFR THS6182RHFT
Manufacturer's Classification
- Semiconductors > Amplifiers > Operational Amplifiers (Op Amps) > High-Speed Op Amps (>=50MHz)