Datasheet Texas Instruments INA110SG

ManufacturerTexas Instruments
SeriesINA110
Part NumberINA110SG
Datasheet Texas Instruments INA110SG

Fast-Settling FET-Input Very High Accuracy Instrumentation Amplifier 16-CDIP SB

Datasheets

Fast-Settling FET-Input Instrumentation Amp datasheet
PDF, 501 Kb, Revision: A, File published: Jul 21, 2005
Extract from the document

Prices

Status

Lifecycle StatusNRND (Not recommended for new designs)
Manufacture's Sample AvailabilityNo

Packaging

Pin16
Package TypeJD
Industry STD TermCDIP SB
JEDEC CodeR-CDIP-T
Package QTY1
CarrierTUBE
Device MarkingINA110SG
Width (mm)7.37
Length (mm)20.57
Thickness (mm)3.5
Pitch (mm)2.54
Max Height (mm)4.45
Mechanical DataDownload

Parametrics

Bandwidth at Min Gain(Typ)2.5 MHz
CMRR(Min)106 dB
Gain Error (+/-)(Max)0.5 %
Gain Non-Linearity (+/-)(Max)0.01 %
Gain(Max)1000 V/V
Gain(Min)1 V/V
Input Bias Current (+/-)(Max)0.05 nA
Input Offset (+/-)(Max)250 uV
Input Offset Drift (+/-)(Max)2 uV/C
Iq(Typ)3 mA
Noise at 0.1 Hz - 10 Hz(Typ)1 uVpp
Noise at 1kHz(Typ)(nV/rt10 Hz
Number of Channels1
Operating Temperature Range-55 to 125 C
Package GroupPDIP,SOIC
Package Size: mm2:W x LSee datasheet (PDIP),16SOIC: 106 mm2: 10.3 x 10.3(SOIC) PKG
RatingCatalog
Vs(Max)36 V
Vs(Min)12 V

Eco Plan

RoHSCompliant

Application Notes

  • AC Coupling Instrumentation and Difference Amplifiers
    PDF, 38 Kb, File published: Sep 27, 2000
    The need to glean AC signals from DC in the presence of common-mode noise frequently occurs in signal conditioning applications. AC coupling to an instrumentation amplifier (IA) or difference amplifier can be used to accurately extract the AC signal while rejecting DC and common-mode noise.

Model Line

Manufacturer's Classification

  • Semiconductors > Amplifiers > Instrumentation Amplifiers