Datasheet Texas Instruments UC3854DWTR-FG4

ManufacturerTexas Instruments
SeriesUC3854
Part NumberUC3854DWTR-FG4
Datasheet Texas Instruments UC3854DWTR-FG4

High Power Factor Preregulator 16-SOIC 0 to 70

Datasheets

UCx854 High-Power Factor Preregulator datasheet
PDF, 949 Kb, Revision: A, File published: Dec 16, 2016
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Packaging

Pin16
Package TypeDW
Industry STD TermSOIC
JEDEC CodeR-PDSO-G
Package QTY2000
CarrierLARGE T&R
Device MarkingUC3854DW-F
Width (mm)7.5
Length (mm)10.3
Thickness (mm)2.35
Pitch (mm)1.27
Max Height (mm)2.65
Mechanical DataDownload

Parametrics

Approx. Price (US$)1.27 | 1ku
Control MethodCCM
Device TypeSingle-phase PFC
Operating Supply Current(mA)10
Operating Supply(Max)(V)30
Operating Temperature Range(C)0 to 70
Package GroupSOIC
Package Size: mm2:W x L (PKG)See datasheet (PDIP)
Peak Output Sink Current Gate Drive(A)1
Peak Output Source Current Gate Drive(A)-1
Practical Operating Frequency(Max)(MHz)0.2
RatingCatalog
Special FeaturesAverage Current Mode
Enable
Startup Current(mA)1.5
UVLO Thresholds On/Off(V)16/10

Eco Plan

RoHSCompliant
Pb FreeYes

Application Notes

  • U-134 UC3854 Controlled Power Factor Correction Circuit Design
    PDF, 346 Kb, File published: Sep 5, 1999
    The UC1854 provides active power factor correction for power systems that otherwise would draw non-sinusoidal current from sinusoidal power lines. This device implements all the control functions necessary to build a power supply capable of optimally using available power-line current while minimizing line-current distortion. This application note describes the concepts and design of a boost prere
  • AC Requirements for Power Factor Correction Circuits
    PDF, 29 Kb, File published: Mar 28, 2002
    This technical brief identifies the recommended range of IAC for each of the devices within the UCC3854 family of PFC controllers.
  • DN-39E Optimizing Performance in UC3854 Power Factor Correction Applications
    PDF, 277 Kb, File published: Sep 5, 1999
    The performance of the UC3854 Power-Factor Correction IC in the 250W application example has been evaluated using a precision PFC/THD instrument. The result was a power factor of 0.999 and Total Harmonic Distortion (THD) of 3.81%, measured to the 50th line frequency harmonic at nominal line and full load. Users should get similar results at these conditions. as well as over most line and load rang
  • Accurate PWM Duty Cycle Clamp
    PDF, 58 Kb, File published: Jan 25, 2002
    Power supply applications using current sense transformers require a duty cycle clamp on the pulse width modulator (PWM) to ensure transformer reset. Not all PWMs come with a duty cycle clamp presenting a problem for the power supply designer. This application note shows how to implement a duty cycle clamp by using a simple delay circuit.
  • DN-41 Extend Current Transformer Range
    PDF, 37 Kb, File published: Sep 5, 1999
    The problems with self reset of current transformers for unipolar pulse applications can be overcome with simple forced-reset techniques derived from magnetic amplifiers. Duty factors above 90% are achievable with these techniques. This design note describes a circuit configured for forced reset and a configuration that generates a negative voltage from the current transformer.

Model Line

Manufacturer's Classification

  • Semiconductors > Power Management > Offline and Isolated DC/DC Controllers and Converters > Power Factor Correction

Other Names:

UC3854DWTRFG4, UC3854DWTR FG4