Datasheet Texas Instruments ADS1194
Manufacturer | Texas Instruments |
Series | ADS1194 |
Low-Power, 4-Channel, 16-Bit Analog Front-End for ECG
Datasheets
Low-Power, 8-Channel, 16-Bit Analog Front-End for Biopotential Measurements datasheet
PDF, 1.6 Mb, Revision: C, File published: Nov 29, 2011
Extract from the document
Prices
Status
ADS1194CPAG | ADS1194CPAGR | ADS1194CZXGR | ADS1194CZXGT | |
---|---|---|---|---|
Lifecycle Status | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) | Active (Recommended for new designs) |
Manufacture's Sample Availability | Yes | Yes | No | No |
Packaging
ADS1194CPAG | ADS1194CPAGR | ADS1194CZXGR | ADS1194CZXGT | |
---|---|---|---|---|
N | 1 | 2 | 3 | 4 |
Pin | 64 | 64 | 64 | 64 |
Package Type | PAG | PAG | ZXG | ZXG |
Industry STD Term | TQFP | TQFP | NFBGA | NFBGA |
JEDEC Code | S-PQFP-G | S-PQFP-G | S-PBGA-N | S-PBGA-N |
Package QTY | 160 | 1500 | 1000 | 250 |
Carrier | JEDEC TRAY (5+1) | LARGE T&R | LARGE T&R | SMALL T&R |
Device Marking | ADS1194 | ADS1194 | ADS1194 | ADS1194 |
Width (mm) | 10 | 10 | 8 | 8 |
Length (mm) | 10 | 10 | 8 | 8 |
Thickness (mm) | 1 | 1 | 1.01 | 1.01 |
Pitch (mm) | .5 | .5 | .8 | .8 |
Max Height (mm) | 1.2 | 1.2 | 1.45 | 1.45 |
Mechanical Data | Download | Download | Download | Download |
Parametrics
Parameters / Models | ADS1194CPAG | ADS1194CPAGR | ADS1194CZXGR | ADS1194CZXGT |
---|---|---|---|---|
# Input Channels | 4 | 4 | 4 | 4 |
Analog Voltage AVDD(Max), V | 5.25 | 5.25 | 5.25 | 5.25 |
Analog Voltage AVDD(Min), V | 2.7 | 2.7 | 2.7 | 2.7 |
Architecture | Delta-Sigma | Delta-Sigma | Delta-Sigma | Delta-Sigma |
Digital Supply(Max), V | 3.6 | 3.6 | 3.6 | 3.6 |
Digital Supply(Min), V | 1.65 | 1.65 | 1.65 | 1.65 |
INL(Max), +/-LSB | 1 | 1 | 1 | 1 |
Input Range(Max), V | 5.25 | 5.25 | 5.25 | 5.25 |
Input Type | Differential,Single-Ended | Differential,Single-Ended | Differential,Single-Ended | Differential,Single-Ended |
Integrated Features | Daisy-Chainable,GPIO,Oscillator,PGA | Daisy-Chainable,GPIO,Oscillator,PGA | Daisy-Chainable,GPIO,Oscillator,PGA | Daisy-Chainable,GPIO,Oscillator,PGA |
Interface | SPI | SPI | SPI | SPI |
Multi-Channel Configuration | Simultaneous Sampling | Simultaneous Sampling | Simultaneous Sampling | Simultaneous Sampling |
Operating Temperature Range, C | 0 to 70 | 0 to 70 | 0 to 70 | 0 to 70 |
Package Group | TQFP | TQFP | NFBGA | NFBGA |
Package Size: mm2:W x L, PKG | 64TQFP: 144 mm2: 12 x 12(TQFP) | 64TQFP: 144 mm2: 12 x 12(TQFP) | 64NFBGA: 64 mm2: 8 x 8(NFBGA) | 64NFBGA: 64 mm2: 8 x 8(NFBGA) |
Power Consumption(Typ), mW | 3 | 3 | 3 | 3 |
Rating | Catalog | Catalog | Catalog | Catalog |
Reference Mode | Int,Ext | Int,Ext | Int,Ext | Int,Ext |
Resolution, Bits | 16 | 16 | 16 | 16 |
SNR, dB | 97 | 97 | 97 | 97 |
Sample Rate (max), SPS | 8KSPS | 8KSPS | 8KSPS | 8KSPS |
Sample Rate(Max), MSPS | 0.008 | 0.008 | 0.008 | 0.008 |
THD(Typ), dB | -95 | -95 | -95 | -95 |
Eco Plan
ADS1194CPAG | ADS1194CPAGR | ADS1194CZXGR | ADS1194CZXGT | |
---|---|---|---|---|
RoHS | Compliant | Compliant | Compliant | Compliant |
Application Notes
- Thermal Noise Analysis in ECG ApplicationsPDF, 114 Kb, File published: May 3, 2011
This article discusses the thermal noise source of electrocardiogram (ECG) applications basedon the ADS1298 and ADS1298R family of multichannel, simultaneous sampling, 24-bit, delta-sigma (О”ОЈ) analog-to-digital converters (ADCs). This report offers several observations on identifying the major sources of thermal noise in an ECG system, and makes several recommendations regarding how to improve t - Improving Common-Mode Rejection Using the Right-Leg Drive AmplifierPDF, 297 Kb, File published: Jul 6, 2011
This article discusses the need to improve common-mode rejection (CMR) in electrocardiogram (ECG) subsystem applications. Several different techniques to improve CMR while also considering both patient and operator safety are presented. This report also reviews the implementation of the right-leg drive (RLD) loop technique to improve CMR using the ADS129x family of analog-to-digital converters (in - Analog Front-End Design for ECG Systems Using Delta-Sigma ADCs (Rev. A)PDF, 191 Kb, Revision: A, File published: Apr 13, 2010
This document discusses the characteristics of electrocardiogram (ECG) signals and different front-endapproaches for ECG signal acquisition. The tradeoffs between different approaches and the effects on overall system design are discussed. The report also includes descriptions of potential implementations of the front-end architecture using the ADS1258 and ADS1278 and respective noise measuremen - Analog-to-Digital Converter Grounding Practices Affect System Performance (Rev. A)PDF, 69 Kb, Revision: A, File published: May 18, 2015
- A Glossary of Analog-to-Digital Specifications and Performance Characteristics (Rev. B)PDF, 425 Kb, Revision: B, File published: Oct 9, 2011
This glossary is a collection of the definitions of Texas Instruments' Delta-Sigma (О”ОЈ), successive approximation register (SAR), and pipeline analog-to-digital (A/D) converter specifications and performance characteristics. Although there is a considerable amount of detail in this document, the product data sheet for a particular product specification is the best and final reference. - Principles of Data Acquisition and Conversion (Rev. A)PDF, 132 Kb, Revision: A, File published: Apr 16, 2015
Model Line
Series: ADS1194 (4)
Manufacturer's Classification
- Semiconductors> Data Converters> Analog-to-Digital Converters (ADCs)> Precision ADCs (<=10MSPS)