Datasheet Texas Instruments ADS1292RIPBSR

ManufacturerTexas Instruments
SeriesADS1292R
Part NumberADS1292RIPBSR
Datasheet Texas Instruments ADS1292RIPBSR

2-Channel, 24-Bit Analog-To-Digital Converter w/Integrated Respiration Impedance and ECG Front End 32-TQFP -40 to 85

Datasheets

Low-Power, 2-Channel, 24-Bit Analog Front-End for Biopotential Measurements datasheet
PDF, 2.0 Mb, Revision: B, File published: Sep 4, 2012
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

Packaging

Pin32
Package TypePBS
Industry STD TermTQFP
JEDEC CodeS-PQFP-G
Package QTY1000
CarrierLARGE T&R
Device Marking1292R
Width (mm)5
Length (mm)5
Thickness (mm)1
Pitch (mm).5
Max Height (mm)1.2
Mechanical DataDownload

Parametrics

# Input Channels2
Analog Voltage AVDD(Max)5.25 V
Analog Voltage AVDD(Min)2.7 V
ArchitectureDelta-Sigma
Digital Supply(Max)3.6 V
Digital Supply(Min)1.7 V
INL(Max)2 +/-LSB
Input Range(Max)5.25 V
Input TypeDifferential,Single-Ended
Integrated FeaturesDaisy-Chainable,GPIO,Oscillator,PGA
InterfaceSPI
Multi-Channel ConfigurationSimultaneous Sampling
Operating Temperature Range-40 to 85 C
Package GroupTQFP
Package Size: mm2:W x L32TQFP: 49 mm2: 7 x 7(TQFP) PKG
Power Consumption(Typ)0.7 mW
RatingCatalog
Reference ModeInt,Ext
Resolution24 Bits
SNR107 dB
Sample Rate (max)8kSPS SPS
Sample Rate(Max)0.008 MSPS
THD(Typ)-104 dB

Eco Plan

RoHSCompliant

Design Kits & Evaluation Modules

  • Evaluation Modules & Boards: ADS1292RECG-FE
    ADS1292R Performance Demonstration Kit
    Lifecycle Status: Active (Recommended for new designs)

Application Notes

  • Respiration Rate Measurement Using Impedance Pneumography
    PDF, 697 Kb, File published: Mar 1, 2011
    This document discusses the use of impedance pneumography as a technique to measure respiration rate. The generation of high-frequency ac current source is described, and the issues related to delay in modulated signal and finite transition times of carriers are addressed. The report also includesdescriptions of potential implementations of a respiration rate measurement system using the ADS1298
  • Understanding Lead-Off Detection in ECG (Rev. A)
    PDF, 313 Kb, Revision: A, File published: Jan 14, 2015
  • Improving Common-Mode Rejection Using the Right-Leg Drive Amplifier
    PDF, 297 Kb, File published: Jul 6, 2011
    This article discusses the need to improve common-mode rejection (CMR) in electrocardiogram (ECG) subsystem applications. Several different techniques to improve CMR while also considering both patient and operator safety are presented. This report also reviews the implementation of the right-leg drive (RLD) loop technique to improve CMR using the ADS129x family of analog-to-digital converters (in
  • Analog Front-End Design for ECG Systems Using Delta-Sigma ADCs (Rev. A)
    PDF, 191 Kb, Revision: A, File published: Apr 13, 2010
    This document discusses the characteristics of electrocardiogram (ECG) signals and different front-endapproaches for ECG signal acquisition. The tradeoffs between different approaches and the effects on overall system design are discussed. The report also includes descriptions of potential implementations of the front-end architecture using the ADS1258 and ADS1278 and respective noise measuremen
  • Digital Filter Types in Delta-Sigma ADCs
    PDF, 219 Kb, File published: Jun 27, 2017
    This application report discusses digital filters which are a ubiquitous feature in delta-sigma analog todigital converters (ADCs). Digital low-pass filters are essential to the functionality of a delta-sigma ADCwhich relies on oversampling and noise shaping to push quantization noise out of band. There arevariations between the types of digital filters used in delta-sigma ADCs that provide
  • Analog-to-Digital Converter Grounding Practices Affect System Performance (Rev. A)
    PDF, 69 Kb, Revision: A, File published: May 18, 2015
  • A Glossary of Analog-to-Digital Specifications and Performance Characteristics (Rev. B)
    PDF, 425 Kb, Revision: B, File published: Oct 9, 2011
    This glossary is a collection of the definitions of Texas Instruments' Delta-Sigma (О”ОЈ), successive approximation register (SAR), and pipeline analog-to-digital (A/D) converter specifications and performance characteristics. Although there is a considerable amount of detail in this document, the product data sheet for a particular product specification is the best and final reference.
  • Principles of Data Acquisition and Conversion (Rev. A)
    PDF, 132 Kb, Revision: A, File published: Apr 16, 2015

Model Line

Manufacturer's Classification

  • Semiconductors > Data Converters > Analog-to-Digital Converters (ADCs) > Precision ADCs (<=10MSPS)