Datasheet Texas Instruments MPC507

ManufacturerTexas Instruments
SeriesMPC507
Datasheet Texas Instruments MPC507

8-Channel Differential-Input Analog Multiplexer

Datasheets

MPC506, MPC507:Single-Ended 16-Chan/Differential 8-Chan CMOS Analog Multiplexers datasheet
PDF, 727 Kb, Revision: A, File published: Sep 17, 2003
Extract from the document

Prices

Status

MPC507AUMPC507AU/1KMPC507AUG4
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityNoNoNo

Packaging

MPC507AUMPC507AU/1KMPC507AUG4
N123
Pin282828
Package TypeDWDWDW
Industry STD TermSOICSOICSOIC
JEDEC CodeR-PDSO-GR-PDSO-GR-PDSO-G
Package QTY20100020
CarrierTUBELARGE T&RTUBE
Device MarkingMPC507AUMPC507AUMPC507AU
Width (mm)7.57.57.5
Length (mm)17.917.917.9
Thickness (mm)2.352.352.35
Pitch (mm)1.271.271.27
Max Height (mm)2.652.652.65
Mechanical DataDownloadDownloadDownload

Parametrics

Parameters / ModelsMPC507AU
MPC507AU
MPC507AU/1K
MPC507AU/1K
MPC507AUG4
MPC507AUG4
Additional FeaturesDual supply,Powered off protection,Overvoltage Protection,Break-before-makeDual supply,Powered off protection,Overvoltage Protection,Break-before-makeDual supply,Powered off protection,Overvoltage Protection,Break-before-make
Configuration8:18:18:1
Input/Ouput Voltage(Max), V151515
Input/Ouput Voltage(Min), V-15-15-15
Input/Output Continuous Current(Max), mA202020
Input/Output OFF-state Capacitance(Typ), pF555
Number of Channels222
OFF-state leakage current(Max), µA0.010.010.01
ON-state leakage current(Max), µA0.010.010.01
Operating Temperature Range, C-40 to 85-40 to 85-40 to 85
Package GroupSOICSOICSOIC
Package Size: mm2:W x L, PKG28SOIC: 184 mm2: 10.3 x 17.9(SOIC)28SOIC: 184 mm2: 10.3 x 17.9(SOIC)28SOIC: 184 mm2: 10.3 x 17.9(SOIC)
RatingCatalogCatalogCatalog
Ron(Max), Ohms180018001800
Ron(Typ), Ohms130013001300
Supply Current(Max), uA150015001500
Supply Current(Typ), uA700700700
Supply Range, Max151515
VIH(Min), V444
VIL(Max), V0.80.80.8
Vdd(Max), V151515
Vdd(Min), V555
Vss(Max), V-5-5-5
Vss(Min), V-15-15-15

Eco Plan

MPC507AUMPC507AU/1KMPC507AUG4
RoHSCompliantCompliantCompliant

Application Notes

  • Multiplexer Data Acquisition System
    PDF, 71 Kb, File published: Oct 4, 2000
    Multiplexers have been used for acquisition of quasi-static signals for a long time. While these signals usually have a low bandwidth of only a few hertz, applications generally require that the multiplexer send each signal as fast as possible to the converter and that the signals be processed quickly. To ensure fast processing, such acquisition systems usually include a sense amplifier behind the

Model Line

Series: MPC507 (3)

Manufacturer's Classification

  • Semiconductors> Switches and Multiplexers> Analog Switches/Muxes