Datasheet Microchip MCP120
Manufacturer | Microchip |
Series | MCP120 |
The MCP120 is a voltage supervisory device designed to keep a microcontroller in reset until the system voltage has reached the proper level and stabilized
Datasheets
Prices
Status
MCP120-270DI/TO | MCP120-270GI/TO | MCP120-270HI/TO | MCP120-270I/SN | MCP120-300DI/TO | MCP120-300GI/TO | MCP120-300HI/TO | MCP120-300I/SN | MCP120-315DI/TO | MCP120-315GI/TO | MCP120-315HI/TO | MCP120-315I/SN | MCP120-450DI/TO | MCP120-450GI/TO | MCP120-450HI/TO | MCP120-450I/SN | MCP120-460DI/TO | MCP120-460GI/TO | MCP120-460HI/TO | MCP120-460I/SN | MCP120-475DI/TO | MCP120-475GI/TO | MCP120-475HI/TO | MCP120-475I/SN | MCP120-485DI/TO | MCP120-485GI/TO | MCP120-485HI/TO | MCP120-485I/SN | MCP120T-270I/SN | MCP120T-270I/TT | MCP120T-300I/SN | MCP120T-300I/TT | MCP120T-315I/SN | MCP120T-315I/TT | MCP120T-450I/SN | MCP120T-450I/TT | MCP120T-460I/SN | MCP120T-460I/TT | MCP120T-475I/SN | MCP120T-475I/TT | MCP120T-485I/SN | MCP120T-485I/TT | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lifecycle Status | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) | Production (Appropriate for new designs but newer alternatives may exist) |
Packaging
MCP120-270DI/TO | MCP120-270GI/TO | MCP120-270HI/TO | MCP120-270I/SN | MCP120-300DI/TO | MCP120-300GI/TO | MCP120-300HI/TO | MCP120-300I/SN | MCP120-315DI/TO | MCP120-315GI/TO | MCP120-315HI/TO | MCP120-315I/SN | MCP120-450DI/TO | MCP120-450GI/TO | MCP120-450HI/TO | MCP120-450I/SN | MCP120-460DI/TO | MCP120-460GI/TO | MCP120-460HI/TO | MCP120-460I/SN | MCP120-475DI/TO | MCP120-475GI/TO | MCP120-475HI/TO | MCP120-475I/SN | MCP120-485DI/TO | MCP120-485GI/TO | MCP120-485HI/TO | MCP120-485I/SN | MCP120T-270I/SN | MCP120T-270I/TT | MCP120T-300I/SN | MCP120T-300I/TT | MCP120T-315I/SN | MCP120T-315I/TT | MCP120T-450I/SN | MCP120T-450I/TT | MCP120T-460I/SN | MCP120T-460I/TT | MCP120T-475I/SN | MCP120T-475I/TT | MCP120T-485I/SN | MCP120T-485I/TT | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
N | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 | 21 | 22 | 23 | 24 | 25 | 26 | 27 | 28 | 29 | 30 | 31 | 32 | 33 | 34 | 35 | 36 | 37 | 38 | 39 | 40 | 41 | 42 |
Package | TO-92 | TO-92 | TO-92 | SOIC | TO-92 | TO-92 | TO-92 | SOIC | TO-92 | TO-92 | TO-92 | SOIC | TO-92 | TO-92 | TO-92 | SOIC | TO-92 | TO-92 | TO-92 | SOIC | TO-92 | TO-92 | TO-92 | SOIC | TO-92 | TO-92 | TO-92 | SOIC | SOIC | SOT-23 | SOIC | SOT-23 | SOIC | SOT-23 | SOIC | SOT-23 | SOIC | SOT-23 | SOIC | SOT-23 | SOIC | SOT-23 |
Pins | 3 | 3 | 3 | 8 | 3 | 3 | 3 | 8 | 3 | 3 | 3 | 8 | 3 | 3 | 3 | 8 | 3 | 3 | 3 | 8 | 3 | 3 | 3 | 8 | 3 | 3 | 3 | 8 | 8 | 3 | 8 | 3 | 8 | 3 | 8 | 3 | 8 | 3 | 8 | 3 | 8 | 3 |
Parametrics
Parameters / Models | MCP120-270DI/TO | MCP120-270GI/TO | MCP120-270HI/TO | MCP120-270I/SN | MCP120-300DI/TO | MCP120-300GI/TO | MCP120-300HI/TO | MCP120-300I/SN | MCP120-315DI/TO | MCP120-315GI/TO | MCP120-315HI/TO | MCP120-315I/SN | MCP120-450DI/TO | MCP120-450GI/TO | MCP120-450HI/TO | MCP120-450I/SN | MCP120-460DI/TO | MCP120-460GI/TO | MCP120-460HI/TO | MCP120-460I/SN | MCP120-475DI/TO | MCP120-475GI/TO | MCP120-475HI/TO | MCP120-475I/SN | MCP120-485DI/TO | MCP120-485GI/TO | MCP120-485HI/TO | MCP120-485I/SN | MCP120T-270I/SN | MCP120T-270I/TT | MCP120T-300I/SN | MCP120T-300I/TT | MCP120T-315I/SN | MCP120T-315I/TT | MCP120T-450I/SN | MCP120T-450I/TT | MCP120T-460I/SN | MCP120T-460I/TT | MCP120T-475I/SN | MCP120T-475I/TT | MCP120T-485I/SN | MCP120T-485I/TT |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Manual Reset | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
Nominal Reset Voltage, V | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 | 2.7, 3, 3.15, 4.5, 4.6, 4.75, 4.85 |
Operating Temp. Range, °C | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 | -40 to 85 |
Operating Temperature Range, °C | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 | -40 to +85 |
Output | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain | Open-Drain |
Power Fail | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
Product Type | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor | Supervisor |
Reset Type | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low | Active Low |
Typical Reset Pulse Width, ms | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 | 350 |
Typical Supply Current, µA | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 | 45 |
VCC Range, V | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 | 1.0 - 5.5 |
Watchdog Timer | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No | No |
Eco Plan
Other Options
Model Line
Series: MCP120 (42)
- MCP120-270DI/TO MCP120-270GI/TO MCP120-270HI/TO MCP120-270I/SN MCP120-300DI/TO MCP120-300GI/TO MCP120-300HI/TO MCP120-300I/SN MCP120-315DI/TO MCP120-315GI/TO MCP120-315HI/TO MCP120-315I/SN MCP120-450DI/TO MCP120-450GI/TO MCP120-450HI/TO MCP120-450I/SN MCP120-460DI/TO MCP120-460GI/TO MCP120-460HI/TO MCP120-460I/SN MCP120-475DI/TO MCP120-475GI/TO MCP120-475HI/TO MCP120-475I/SN MCP120-485DI/TO MCP120-485GI/TO MCP120-485HI/TO MCP120-485I/SN MCP120T-270I/SN MCP120T-270I/TT MCP120T-300I/SN MCP120T-300I/TT MCP120T-315I/SN MCP120T-315I/TT MCP120T-450I/SN MCP120T-450I/TT MCP120T-460I/SN MCP120T-460I/TT MCP120T-475I/SN MCP120T-475I/TT MCP120T-485I/SN MCP120T-485I/TT
Manufacturer's Classification
- Power Management > Voltage Detectors