Datasheet Texas Instruments HDC2010YPAR

ManufacturerTexas Instruments
SeriesHDC2010
Part NumberHDC2010YPAR
Datasheet Texas Instruments HDC2010YPAR

Low Power Humidity and Temperature Digital Sensor 6-DSBGA -40 to 85

Datasheets

HDC2010 Low Power Humidity and Temperature Digital Sensors datasheet
PDF, 1.4 Mb, File published: Jul 16, 2017
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityYes

Packaging

Pin6
Package TypeYPA
Industry STD TermDSBGA
JEDEC CodeS-XBGA-N
Package QTY3000
CarrierLARGE T&R
Device MarkingL
Pitch (mm).5
Max Height (mm).675
Mechanical DataDownload

Parametrics

Average Supply Current(Typ)0.55 @ 1 sample/sec uA
InterfaceI2C
Operating Temperature Range-40 to 85 C
RatingCatalog
Relative Humidity Accuracy(Typ)В±2 %RH
Relative Humidity Operating Range(Typ)0 - 100 %RH
Supply Voltage3.6 Min
Temperature Accuracy(Typ)0.2 В°C

Eco Plan

RoHSCompliant

Design Kits & Evaluation Modules

  • Evaluation Modules & Boards: HDC2010EVM
    HDC2010 Low Power Humidity and Temperature Sensor Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

Application Notes

  • Optimizing Placement and Routing for Humidity Sensors (Rev. A)
    PDF, 1.3 Mb, Revision: A, File published: Mar 6, 2017
    Humidity affects many properties of air, and of materials in contact with air. Water vapor is the key agentin both weather and climate, and it is an important atmospheric greenhouse gas. Humidity measurementsare used wherever there is a need to prevent condensation, corrosion, mold, warping or other spoilage ofproducts. This is highly relevant for foods, pharmaceuticals, chemicals, fuels, wo
  • AN-1112 DSBGA Wafer Level Chip Scale Package (Rev. AG)
    PDF, 13.7 Mb, Revision: AG, File published: Aug 12, 2015

Model Line

Series: HDC2010 (2)

Manufacturer's Classification

  • Semiconductors > Sensing Products > Humidity Sensors