Datasheet AD7782 (Analog Devices) - 6

ManufacturerAnalog Devices
Description2-Channel, Read-Only, Pin-Configured, 24-bit Sigma-Delta ADC
Pages / Page13 / 6 — AD7782. CH1/CH2 (I). CS (I). DOUT/RDY. MSB. LSB. t10. SLAVE MODE. SCLK …
RevisionA
File Format / SizePDF / 648 Kb
Document LanguageEnglish

AD7782. CH1/CH2 (I). CS (I). DOUT/RDY. MSB. LSB. t10. SLAVE MODE. SCLK (I). t11. MASTER MODE. SCLK (O)

AD7782 CH1/CH2 (I) CS (I) DOUT/RDY MSB LSB t10 SLAVE MODE SCLK (I) t11 MASTER MODE SCLK (O)

Model Line for this Datasheet

Text Version of Document

AD7782 CH1/CH2 (I) t2 CS (I) t3 t t 9 t8 4 DOUT/RDY MSB LSB MSB LSB t5 t10 t7 SLAVE MODE SCLK (I) t6 t5 t11 MASTER MODE t7 SCLK (O) t6 I = INPUT TO AD7782, O = OUTPUT FROM AD7782
MASTER MODE IS SELECTED BY TYING THE MODE PIN LOW, WHEREAS SLAVE MODE IS SELECTED BY TYING THE MODE PIN HIGH. Figure 2. Slave/Master Mode Timing Diagram
ABSOLUTE MAXIMUM RATINGS*
TSSOP Package (T θ A = 25°C unless otherwise noted) JA Thermal Impedance . 97.9°C/W VDD to GND . –0.3 V to +7 V θJC Thermal Impedance . 14°C/W Analog Input Voltage to GND . –0.3 V to VDD + 0.3 V Lead Temperature, Soldering Reference Input Voltage to GND . –0.3 V to VDD + 0.3 V Vapor Phase (60 sec) . 215°C Total AIN/REFIN Current (Indefinite) . 30 mA Infrared (15 sec) . 220°C Digital Input Voltage to GND . –0.3 V to VDD + 0.3 V *Stresses above those listed under Absolute Maximum Ratings may cause per- Digital Output Voltage to GND . –0.3 V to VDD + 0.3 V manent damage to the device. This is a stress rating only; functional operation of Operating Temperature Range . –40°C to +85°C the device at these or any other conditions above those listed in the operational Storage Temperature Range . –65°C to +150°C sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Junction Temperature . 150°C
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on the human body and test equipment and can discharge without detection. Although
WARNING!
the AD7782 features proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high-energy electrostatic discharges. Therefore, proper ESD precautions are
ESD SENSITIVE DEVICE
recommended to avoid performance degradation or loss of functionality. REV. A –5–