TABLE I. Electrical performance characteristics – Continued. 1/ Test Symbol Conditions 2/ Temperature, Device Limits Unit TA type Min Max Undervoltage lock out (UVLO) Positive going -55C to +125C 01 2.96 V threshold 25C 2.8 typical Negative going -55C to +125C 01 2.4 V threshold 25C 2.6 typical EAOUT impedance VDD2 or VDD1 UVLO threshold 25C 01 High-Z typical Output characteristics. See figure 5 Output gain 3/ From COMP to EAOUT, -55C to +125C 01 0.83 1.17 V/V 0.4 V to 2.1 V, 3 mA 25C 1.0 typical From EAOUT to EAOUT2, -55C to +125C 2.5 2.7 0.4 V to 2.1 V, 1 mA, VDD1 = 20 V 25C 2.6 typical Output offset voltage From COMP to EAOUT, -55C to +125C 01 -0.4 +0.4 V 0.4 V to 2.1 V, 3 mA 25C +0.05 typical From EAOUT to EAOUT2, -55C to +125C -0.1 +0.1 0.4 V to 2.1 V, 1 mA, VDD1 = 20 V 25C +0.01 typical Output linearity 4/ From COMP to EAOUT, -55C to +125C 01 -1.0 +1.0 % 0.4 V to 2.1 V, 3 mA 25C +0.15 typical From EAOUT to EAOUT2, -55C to +125C -1.0 +1.0 0.4 V to 2.1 V, 1 mA, VDD1 = 20 V 25C +0.1 typical Output -3 dB bandwidth From COMP to EAOUT, -55C to +125C 01 250 kHz 0.4 V to 2.1 V, 3 mA and from COMP to EAOUT2, 25C 400 typical 0.4 V to 2.1 V, 1 mA, VDD1 = 20 V See footnotes at end of table. DLA LAND AND MARITIME SIZE CODE IDENT NO. DWG NO. COLUMBUS, OHIOA16236V62/17602 REV PAGE 6