TABLE I. Electrical performance characteristics. Conditions Test Symbol -55°C ≤ TA ≤+125°C Group A Device Limits Unit VCC = ±15 V, RS = 50 Ω subgroups type unless otherwise specified Min Max Input offset voltage VIO 1 01 -75 +75 µV 2, 3 -125 +125 Input offset current IIO VCM = 0 V 1 01 -1.0 +1.0 nA 2, 3 -2.5 +2.5 Input bias current ±IIB VCM = 0 V 1 01 -2.0 +2.0 nA 2, 3 -5.0 +5.0 Common mode rejection CMRR VCM = IVR = ±11 V 1 01 120 dB ratio 1/ 2, 3 115 Power supply rejection ratio PSRR VCC = ±3 V to ±18 V 1 01 1.8 µV/V 2, 3 3.2 Supply current no load 2/ ISY 1 01 1.45 mA 2, 3 1.55 Large signal voltage gain AVS VOUT = ±10 V, RL = 2 kΩ 1 01 2000 V/mV 2, 3 1000 VOUT = ±10 V, RL = 10 kΩ 1 5000 2, 3 3000 Output voltage swing +VOP RL = 2 kΩ 1, 2, 3 01 +11 V RL = 10 kΩ +12 -VOP RL = 2 kΩ 1, 2, 3 -11 RL = 10 kΩ -12 Input noise voltage En fO = 1 Hz to 100 Hz, 4 01 250 nVrms TA = +25°C Slew rate SR TA = +25°C, AV = +1 4 01 0.05 V/µs Input offset voltage TCVIO TA = +125°C, -55°C 2, 3 01 0.5 µV/°C temperature coefficient 1/ IVR is defined as the VCM range used for the CMRR test. 2/ ISY limit = total of all two amplifiers. STANDARD SIZE 5962-88593MICROCIRCUIT DRAWINGA DLA LAND AND MARITIME REVISION LEVEL SHEET COLUMBUS, OHIO 43218-3990 F 5 DSCC FORM 2234 APR 97 Document Outline DEPARTMENT OF DEFENSE SPECIFICATION DEPARTMENT OF DEFENSE STANDARDS