LTM8062/LTM8062A operaTion FLOAT VOLTAGE RECHARGE THRESHOLD BATTERY VOLTAGE PRECONDITION THRESHOLD MAXIMUM CHARGE CURRENT BATTERY CHARGE CURRENT PRECONDITION CURRENT C/10 0 AMPS 1 CHRG 0 FAULT 1 0 1 RUN 0 8062 F01 Figure 1. Typical C/10 Terminated Charge Cycle (TMR Grounded, Time Not to Scale) FLOAT VOLTAGE RECHARGE THRESHOLD BATTERY VOLTAGE PRECONDITION THRESHOLD MAXIMUM CHARGE CURRENT BATTERY CHARGE CURRENT PRECONDITION CURRENT C/10 CURRENT 1 CHRG 0 FAULT 1 0 1 RUN 0 < tEOC/8 tEOC AUTOMATIC RESTART 8062 F02 Figure 2. Typical EOC (Timer-Based) Terminated Charge Cycle(Capacitor Connected to TMR, Time Not to Scale) 8062fd 10 For more information www.linear.com/LTM8062 Document Outline Features Applications Description Typical Application Absolute Maximum Ratings Pin Configuration Order Information Electrical Characteristics Typical Performance Characteristics Pin Functions Applications Information Typical Application Related Parts