Datasheet ACS715 (Allegro) - 8

ManufacturerAllegro
DescriptionAutomotive Grade, Fully Integrated, Hall Effect-Based Linear Current Sensor IC with 2.1 kVRMS Voltage Isolation and a Low-Resistance Current Conductor
Pages / Page16 / 8 — Automotive Grade, Fully Integrated, Hall-Effect-Based Linear Current …
File Format / SizePDF / 1.0 Mb
Document LanguageEnglish

Automotive Grade, Fully Integrated, Hall-Effect-Based Linear Current Sensor IC. ACS715

Automotive Grade, Fully Integrated, Hall-Effect-Based Linear Current Sensor IC ACS715

Model Line for this Datasheet

Text Version of Document

Automotive Grade, Fully Integrated, Hall-Effect-Based Linear Current Sensor IC ACS715 with 2.1 kVRMS Voltage Isolation and Low-Resistance Current Conductor x30A PERFORMANCE CHARACTERISTICS over Range E: TA = –40°C to 85°C1, CF = 1 nF, and VCC = 5 V, unless otherwise speci- fied Characteristic Symbol Test Conditions Min. Typ. Max. Units
Optimized Accuracy Range IP 0 – 30 A Sensitivity Sens Over full range of IP, IP applied for 5 ms; TA = 25°C 129 133 137 mV/A Peak-to-peak, TA = 25°C, 2 kHz external filter, 133 mV/A Noise VNOISE(PP) programmed Sensitivity, CF = 47 nF, COUT = 10 nF, 2 kHz – 15 – mV bandwidth T Zero Current Output Slope ∆V A = –40°C to 25°C – 0.06 – mV/°C OUT(Q) TA = 25°C to 150°C – 0.1 – mV/°C T Sensitivity Slope ∆Sens A = –40°C to 25°C – 0.007 – mV/A/°C TA = 25°C to 150°C – –0.025 – mV/A/°C Electrical Output Voltage VOE IP = 0 A –30 – 30 mV Total Output Error2 ETOT IP = 30 A , IP applied for 5 ms; TA = 25°C – ±1.5 – % 1Device may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature, TJ(max), is not exceeded. 2Percentage of IP, with IP = 30 A. Output filtered.
x30A PERFORMANCE CHARACTERISTICS over Range L: TA = –40°C to 150°C1, CF = 1 nF, and VCC = 5 V, unless otherwise specified Characteristic Symbol Test Conditions Min. Typ. Max. Units
Optimized Accuracy Range IP 0 – 30 A Over full range of I Sensitivity Sens P, IP applied for 5 ms; TA = 25°C – 133 – mV/A Over full range of IP, TA = –40°C to 150°C 125 – 137 mV/A Peak-to-peak, TA = 25°C, 2 kHz external filter, 133 mV/A Noise VNOISE(PP) programmed Sensitivity, CF = 47 nF, COUT = 10 nF, 2 kHz – 15 – mV bandwidth T Zero Current Output Slope ∆V A = –40°C to 25°C – 0.06 – mV/°C OUT(Q) TA = 25°C to 150°C – 0.1 – mV/°C T Sensitivity Slope ∆Sens A = –40°C to 25°C – 0.007 – mV/A/°C TA = 25°C to 150°C – –0.025 – mV/A/°C I Electrical Output Voltage V P = 0 A, TA = 25ºC –40 – 40 mV OE IP = 0 A, TA = –40ºC to 150ºC –60 – 60 mV I Total Output Error2 E P = 30 A , IP applied for 5 ms; TA = 25°C – ±1.5 – % TOT IP = 30 A , IP applied for 5 ms; TA = –40°C to 150°C –5 – 5 % 1Device may be operated at higher primary current levels, IP, and ambient temperatures, TA, provided that the Maximum Junction Temperature, TJ(max), is not exceeded. 2Percentage of IP, with IP = 30 A. Output filtered. 7 Allegro MicroSystems 955 Perimeter Road Manchester, NH 03103-3353 U.S.A. www.allegromicro.com