Datasheet for Consumer R1540x (Ricoh) - 9

ManufacturerRicoh
DescriptionHigh Noise Immunity 42 V Input Voltage 70 mA Voltage Tracker for Consumer Applications
Pages / Page16 / 9 — R1540x. THEORY OF OPERATION Thermal Shutdown
File Format / SizePDF / 901 Kb
Document LanguageEnglish

R1540x. THEORY OF OPERATION Thermal Shutdown

R1540x THEORY OF OPERATION Thermal Shutdown

Model Line for this Datasheet

Text Version of Document

R1540x
NO.EA-513-190411
THEORY OF OPERATION Thermal Shutdown
Thermal Shutdown occurs when the device’s junction temperature reaches 165°C (Typ.) at which point the regulator will automatically shut down. Then the regulator resumes from the stand-by state when the junction temperature decreases below 135°C (Typ.). Unless the cause of overheating is eliminated, the device cycles on and off to generate pulse output. 9