Datasheet AK9730AJF21 (Asahi Kasei Microdevices) - 9

ManufacturerAsahi Kasei Microdevices
DescriptionIR Sensor for NDIR Gas Sensing
Pages / Page10 / 9 — 13. Precautions. <Electrostatic Discharge (ESD)>. <Storage …
File Format / SizePDF / 640 Kb
Document LanguageEnglish

13. Precautions. <Electrostatic Discharge (ESD)>. <Storage Environment>. <Other Precautions>

13 Precautions <Electrostatic Discharge (ESD)> <Storage Environment> <Other Precautions>

Model Line for this Datasheet

Text Version of Document

[AK9730AJF21]
13. Precautions <Electrostatic Discharge (ESD)>
This product is sensitive to Electrostatic Discharge (ESD). When handling the product, please be careful about the following matters. When you handle the product, please work in the environment to protect against static electricity (ex. more than 40%RH). Always use an ESD wrist strap and wear antistatic clothes. Please take electrostatic measures of the container etc. where the product touches directly.
<Storage Environment>
Please avoid exposed to direct sunlight. Please keep it as much as possible at room temperature and normal humidity. The desirable condition is 5 ~ 35 C and 40 ~ 85%RH. In addition, please keep the product away from the chlorine gas and the causticity gas. When this product is kept in inappropriate environment, it may influence product properties.
<Other Precautions>
As Gallium Arsenide (GaAs) and Aluminum Indium Antimonide (AlInSb) are used for this product, please be careful about the following matters. 1) Please do not take this product to burning and melting and destroys, chemical processing etc.. 2) When you discard this product, please handle it according to related laws and your regulations on waste disposal. Please be careful not to damage and pollute the sensor surface because the sensor properties may change.
14. Ordering Guide
AK9730AJF21 -40 ~ 85ºC 10-pin SON Industrial Grade
15. Revision History
Date (Y/M/D) Revision Reason Page Contents 19/3/18 00 First Edition 018015023-E-00 2019/3 - 9 -