Datasheet ZMOD4410 (Renesas) - 10

ManufacturerRenesas
DescriptionGas Sensor Module for TVOC and Indoor Air Quality
Pages / Page23 / 10 — Table 6. Level of Air Quality Based on TVOC Levels Described by UBA. …
Revision20201130
File Format / SizePDF / 1.1 Mb
Document LanguageEnglish

Table 6. Level of Air Quality Based on TVOC Levels Described by UBA. Renesas IAQ Rating. Reference Level*. Air Information

Table 6 Level of Air Quality Based on TVOC Levels Described by UBA Renesas IAQ Rating Reference Level* Air Information

Model Line for this Datasheet

Text Version of Document

link to page 10 link to page 9 link to page 10 ZMOD4410 Datasheet The ZMOD4410 can respond reliably to al of the types of organic compounds that are typically found in indoor environments. To assess the response of the gas sensor module to the levels described in the UBA study, the module has been tested using several TO-15/17 multi- component TVOC standards defined by the EPA. The ZMOD4410 response to the EPA standard with the TVOC levels from UBA is shown in Figure 3. A third-party report and certification from an independent research lab is available on the Renesas website that confirms the good conformity for IAQ measurements with respect to the UBA study and EPA standard.
Table 6. Level of Air Quality Based on TVOC Levels Described by UBA Renesas IAQ Rating Reference Level* Air Information TVOC (mg/m3) [a] Air Quality
≤ 1.99 Level 1 Clean Hygienic Air (target value) < 0.3 Very Good 2.00 to 2.99 Level 2 Good Air Quality (if no threshold value is exceeded) 0.3 to 1.0 Good 3.00 to 3.99 Level 3 Noticeable Comfort Concerns (not recommended for exposure > 12 months) 1.0 to 3.0 Medium 4.00 to 4.99 Level 4 Significant Comfort Issues (not recommended for exposure > 1 month) 3.0 to 10.0 Poor ≥ 5.00 Level 5 Unacceptable Conditions (not recommended) > 10.0 Bad [a] Conversion from mg/m3 to ppm for most common TVOC is by the factor approximately 0.5; for example, 10mg/m3 equals approximately 5ppm. Conversion from ppm to ppb is by the factor 1000; for example, 0.1ppm equals 100ppb.
Figure 3. Typical ZMOD4410 Response to Levels of TVOC Described by UBA using EPA Std. Mixture
Note: TVOC is a subset comprising 25 of the EPA’s TO-15/17 certified mixtures. © 2020 Renesas Electronics Corporation 10 November 30, 2020 Document Outline 1. Pin Assignments 2. Pin Descriptions 3. Absolute Maximum Ratings 4. Operating Conditions 5. Electrical Characteristics 6. Block Diagram 7. Sensor Module Characteristics 7.1 Gas Sensor Module 8. Gas Sensor Module Operation Modes and Characteristics 8.1 Operation Modes 1–3 8.1.1 Air Quality – UBA Levels 8.1.2 Air Quality – Estimated Carbon Dioxide Correlation (eCO2) 8.2 Operation Mode 4: Odor 8.3 Operation Mode 5: Sulfur based Odor Discrimination 8.4 Conditioning and Stability 8.5 Environmental Temperature and Humidity 8.6 Accuracy and Consistency 9. Assembly Restrictions, Operation, Integration Notes, and Storage 10. Test and Calibration 11. I2C Interface and Data Transmission Protocol 12. Related Websites and Software 13. Glossary 14. Package Outline Drawings 15. Ordering Information 16. Revision History