Switching Power Supply Mean Well HVGC-100-350
Manufacturer | Mean Well |
Series | HVGC-100 |
Part Number | HVG-100-350 |
Features:
Prices
Detailed Description
- Constant current design
- Wide input range 180~480VAC
- Built-in active PFC function
- High efficiency up to 91%
- Protections: Short circuit / Over voltage / Over temperature
- Cooling by free air convection
- OCP point adjustable through output cable or internal potentiometer
- IP67 / IP65 design for indoor or outdoor installations
- Three in one dimming function (0~10VDC or 10V PWM signal or resistance)
- Suitable for LED lighting and street lighting applications
- Compliance to worldwide safety regulations for lighting
- Suitable for dry / damp / wet locations
- 5 years warranty
HVGС-100 Series Specification
Model
|
HVGC-100-350
|
HVGC-100-700
|
|
Output
|
Rated Current
|
350mA
|
700mA
|
Current Accuracy
|
5.0%
|
||
Max.
Output Voltage |
3 ~ 285V
|
3 ~ 142V
|
|
Rated Power
|
99.75W
|
99.4W
|
|
Ripple & Noise (max)
|
1Vp-p
|
0.5Vp-p
|
|
Current Adj. Range
|
Can be adjusted by internal potentiometer or through output cable
|
||
210 ~ 350mA
|
420 ~ 700mA
|
||
Setup, Rise Time
|
3000ms, 150ms at full load (440VAC / 347VAC);
B type 5000ms, 150ms at 95% load (440VAC / 347VAC) |
||
Hold Up Time (Typ.)
|
30ms at full load (440VAC / 347VAC)
|
||
Input
|
Voltage Range
|
180 ~ 480VAC
254VDC ~ 679VDC |
|
Frequency Range
|
47 ~ 63Hz
|
||
Power Factor (Typ.)
|
PF ≥ 0.98/230VAC, PF ≥ 0.98/277VAC,
PF ≥ 0.97/347VAC, PF ≥ 0.94/440VAC at full load |
||
Efficiency (Typ.)
|
91%
|
91%
|
|
AC Current (Typ.)
|
0.32A / 347VAC
0.26A / 440VAC |
||
Inrush Current ( Typ .)
|
COLD START 50A / 440VAC
|
||
Leakage Current
|
<0.75mA / 440VAC
|
||
Protection
|
Short Circuit
|
Constant current limiting, recovers automatically
after fault condition is removed |
|
Over Voltage
|
300 ~ 320V
|
150 ~ 160V
|
|
Protection type : Shut down o/p voltage with auto-recovery
or re-power on to recovery |
|||
Over Temperature
|
100°C±10°C (RTH2)
|
||
Protection type : Shut down o/p voltage, recovers automatically
after temperature goes down |
|||
Environment
|
Working Temp.
|
–40 ~ +70°C (Refer to "Derating Curve")
|
|
Working Humidity
|
20 ~ 95% RH non-condensing
|
||
Storage Temp., Humidity
|
–40 ~ +80°C , 10 ~ 95% RH
|
||
Temp. Coefficient
|
0.03%/°C (0 ~ 50°C)
|
||
Vibration
|
10 ~ 500Hz, 5G 12min./1cycle,
period for 72min. each along X, Y, Z axes |
||
Safety
& EMC |
Safety Standards
|
UL8750 CSA C22.2 No. 250.0-08, EN61347-1,
EN61347-2-13 independent, approved , IP65 or IP67 |
|
Withstand Voltage
|
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
|
||
Isolation Resistance
|
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
|
||
EMC Emission
|
Compliance to EN55015, EN61000-3-2 Class C ( 50% load);
EN61000-3-3, FCC part 15 class B |
||
EMC Immunity
|
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,
light industry level (surge 4KV), criteria A |
||
Others
|
Dimension
|
236×68×38.8 mm (L×W×H)
|
HVGС-100 Series Mechanical Specification (HVGС-100-_B):
Other Names:
HVG100350, HVG 100 350