Switching Power Supply Mean Well HVG-100-48

ManufacturerMean Well
SeriesHVG-100
Part NumberHVG-100-48

Features:

Prices

Detailed Description

  • Wide input range 180~480VAC
  • Built-in active PFC function
  • High efficiency up to 91%
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • OCP point adjustable through output cable or internal potentiometer
  • IP67 / IP65 design for indoor or outdoor installations
  • Three in one dimming function (0~10VDC or 10V PWM signal or resistance)
  • Suitable for LED lighting and street lighting applications
  • Compliance to worldwide safety regulations for lighting
  • Suitable for dry / damp / wet locations
  • 5 years warranty

Mean Well - HVG-100

HVG-100 Series Specification

Model
HVG-100
-15
HVG-100
-20
HVG-100
-24
HVG-100
-30
HVG-100
-36
HVG-100
-42
HVG-100
-48
HVG-100
-54
Output
DC Voltage
15V
20V
24V
30V
36V
42V
48V
54V
Rated Current
5A
4.8A
4A
3.2A
2.65A
2.28A
2A
1.77A
Rated Power
75W
96W
96W
96W
95.4W
95.76W
96W
95.58W
Ripple & Noise (max)
150mVp-p
150mVp-p
150mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
Voltage Adj.
13.5 ~ 17V
17 ~ 22V
22 ~ 27V
27 ~ 33V
33 ~ 40V
38 ~ 46V
43 ~ 53V
49 ~ 58V
Current Adj.

Range

Can be adjusted by internal potentiometer or through output cable
2.75 ~ 5A
2.64 ~ 4.8A
2.2 ~ 4A
1.76 ~ 3.2A
1.45 ~ 2.65A
1.25 ~ 2.28A
1.1 ~ 2A
0.97 ~ 1.77A
Voltage Tolerance
2.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
Line Regulation
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
Load Regulation
1.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
Setup, Rise Time
2500ms, 80ms at full load     440VAC / 347VAC;
B type 3000ms, 280ms at 95% load     440VAC / 347VAC
Hold Up Time (Typ.)
30ms at full load     440VAC / 347VAC
Input
Voltage Range
180 ~ 480VAC
254VDC ~ 679VDC
Frequency Range
47 ~ 63Hz
Power Factor (Typ.)
PF ≥ 0.98/230VAC, PF ≥ 0.98/277VAC, PF ≥ 0.97/347VAC,
PF ≥ 0.94/440VAC (PF ≥ 0.93/440VAC only for 15 V model) at full load
Efficiency (Typ.)
89%
90%
91%
91%
90.5%
90.5%
91%
91%
AC Current (Typ.)
0.32A / 347VAC
0.26A / 440VAC
Inrush Current (Typ.)
Cold start 50A / 440VAC
Leakage Current
<0.75mA / 440VAC
Protection
Over Current
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Short Circuit
Constant current limiting, recovers automatically after fault condition is removed
Over Voltage
18 ~ 21V
23 ~ 27V
28 ~ 34V
34 ~ 38V
41 ~ 46V
47 ~ 53V
54 ~ 60V
59 ~ 65V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
Over Temperature
100 ±10°C (RTH2)
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Environment
Working Temp.
–40 ~ +70°C (Refer to "Derating Curve")
Working Humidity
20 ~ 95% RH non-condensing
Storage Temp.
–40 ~ +80°C
Storage Humidity
10 ~ 95% RH
Temp. Coefficient
0.03%/°C (0 ~ 50°C)
Vibration
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
Safety &EMC
Safety Standards Note.6
UL8750 CSA C22.2 No. 250.0-08 , approved , (except for 48V,54V) IP65 or IP67
Withstand Voltage
I/P-O/P:3.75KVAC     I/P-FG:1.88KVAC     O/P-FG:0.5KVAC
Isolation Resistance
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C  / 70% RH
EMC Emission
Compliance to EN55015, EN61000-3-2 Class C ( 50% load, 60% load only for 15V model );
EN61000-3-3, FCC part 15 class B
EMC Immunity
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge 4KV), criteria A
Others
Dimension
236×68×38.8   mm (L×W×H)

HVG-100 Series Mechanical Specification (HVG-100-_B):

HVG-100 Series Mechanical Specification
Click to enlarge image

Other Names:

HVG10048, HVG 100 48