Switching Mode power supply Manson NRP-6016
Manufacturer | Manson |
Series | NRP |
Part Number | NRP-6016 |
This series of 100W Switching Mode Power Supplies with Current Limiting Control, is designed with the objectives of high accuracy, compactness and easy portability.
Prices
Detailed Description
Wire wound potentiometers are used for voltage and current control.
4 digit display LCD of voltage and current for high precision.
The slim tower housing makes it ideal for tight work bench. It is light and conveniently portable with a collapsible handle.
The large and illuminated LCD display provides clear and sharp readings even under dim light. The output power on off switch allows safe and handy operations. The Tracking OVP (Output Over Voltage Protection) ensures a better and tighter protection to voltage sensitive loads. It has good line and load regulations, high efficiency and low ripple & noise that are typical of advanced switching mode power supply.
It meets the CE safety standards of EN-61010 for laboratory grade power supply and respective EMC standards.
Features
- Automatic Cross over CV and CC mode
- Illuminated LCD indications of A, V, Output On-OFF, CC & CV.
- 4 digit displays of Volt and Amp meters
- Wire wound potentiometers for Voltage and Current controls
- Voltage and Current controls
- Compact slim tower housing
- Collapsible handle
- Output power on off switch at front panel
- Natural Cinvection
- Tracking OVP (output over voltage protection), Short circuit, overload and over temperature protections.
- Good line, load regulations and low ripple and noise
- CE approvals
Technical Specifications
|
NRP-2050 |
NRP-3630 |
NRP-6016 |
|
Input Voltage (Jumper Selection) |
90…130/180…260 Vac, 50Hz~ |
|||
Full Load Input Current at 230Vac |
0.83A |
|||
Output Voltage Adjustable Range |
1.0…20Vdc |
1.0…36Vdc |
1.0…60Vdc |
|
Output Current Adjustable Range |
0…5A |
0…3A |
0…1.6A |
|
Voltage |
Load from 10% to 100% Variation |
70mV |
50mV |
50mV |
Line from 180 to 264Vac Variation |
20mV |
|||
Ripple & Noise in r.m.s. |
5mV |
|||
Ripple & Noise (peak to peak) |
30mV |
30mV |
50mV |
|
Current |
Load from 10% to 100% Variation |
20mA |
||
Line from 180 to 264Vac Variation |
20mA |
|||
Ripple & Noise (peak to peak) |
20mA |
|||
Switching Operation Frequency |
80KHz to 120KHz |
|||
Power Factor |
0.68 |
|||
Efficiency at Maximum Power |
84% |
85% |
85% |
|
Volt and Amp Potentiometer Type |
Wire Wound |
|||
Voltmeter and Ammeter Display |
3 Digit |
|||
Voltmeter Accuracy |
±1% +5counts |
±1% +5counts |
±1% +5counts |
|
±1% +3counts |
±1% +3counts |
±1% +3counts |
||
Ammeter Accuracy |
±1% +5counts |
±1% +5counts |
±1% +5counts |
|
±1% +3counts |
±1% +3counts |
±1% +3counts |
||
LCD Indication |
CC, CV, Amp, Volt, Output ON-OFF |
|||
Protection |
Short Circuit, Overload , Over Temperature, Tracking OVP |
|||
CE Approvals |
LVD: EN 61010, EMC !: EN 55011 |
|||
Cooling System |
Natural Convection |
|||
Dimensions (W×H×D) |
70 × 150 × 250mm / 2.8 × 6.0 × 9.8in |
|||
Weight |
2Kgs / 4.4Lbs |
Other Names:
NRP6016, NRP 6016