Switching Mode power supply Manson NRP-6016

ManufacturerManson
SeriesNRP
Part NumberNRP-6016

This series of 100W Switching Mode Power Supplies with Current Limiting Control, is designed with the objectives of high accuracy, compactness and easy portability.

Prices

Detailed Description

Wire wound potentiometers are used for voltage and current control.

4 digit display LCD of voltage and current for high precision.

The slim tower housing makes it ideal for tight work bench. It is light and conveniently portable with a collapsible handle.

The large and illuminated LCD display provides clear and sharp readings even under dim light. The output power on off switch allows safe and handy operations. The Tracking OVP (Output Over Voltage Protection) ensures a better and tighter protection to voltage sensitive loads. It has good line and load regulations, high efficiency and low ripple & noise that are typical of advanced switching mode power supply.

It meets the CE safety standards of EN-61010 for laboratory grade power supply and respective EMC standards.

Features

  • Automatic Cross over CV and CC mode
  • Illuminated LCD indications of A, V, Output On-OFF, CC & CV.
  • 4 digit displays of Volt and Amp meters
  • Wire wound potentiometers for Voltage and Current controls
  • Voltage and Current controls
  • Compact slim tower housing
  • Collapsible handle
  • Output power on off switch at front panel
  • Natural Cinvection
  • Tracking OVP (output over voltage protection), Short circuit, overload and over temperature protections.
  • Good line, load regulations and low ripple and noise
  • CE approvals

Switching Mode power supply Manson NRP-6016

Technical Specifications

 

NRP-2050

NRP-3630

NRP-6016

Input Voltage (Jumper Selection)

90…130/180…260 Vac, 50Hz~

Full Load Input Current at 230Vac

0.83A

Output Voltage Adjustable Range

1.0…20Vdc

1.0…36Vdc

1.0…60Vdc

Output Current Adjustable Range

0…5A

0…3A

0…1.6A

Voltage
Regulation

Load from 10% to 100% Variation

70mV

50mV

50mV

Line from 180 to 264Vac Variation

20mV

Ripple & Noise in r.m.s.

5mV

Ripple & Noise (peak to peak)

30mV

30mV

50mV

Current
Regulation

Load from 10% to 100% Variation

20mA

Line from 180 to 264Vac Variation

20mA

Ripple & Noise (peak to peak)

20mA

Switching Operation Frequency

80KHz to 120KHz

Power Factor

0.68

Efficiency at Maximum Power

84%

85%

85%

Volt and Amp Potentiometer Type

Wire Wound

Voltmeter and Ammeter Display

3 Digit

Voltmeter Accuracy

±1% +5counts
for range V ≤ 5V

±1% +5counts
for range V ≤ 10V

±1% +5counts
for range V ≤ 20V

±1% +3counts
for range V > 5V

±1% +3counts
for range V > 10V

±1% +3counts
for range V > 20V

Ammeter Accuracy

±1% +5counts
for range I ≤ 2A

±1% +5counts
for range I ≤ 1A

±1% +5counts
for range I ≤ 0.5A

±1% +3counts
for range I > 2A

±1% +3counts
for range I > 1A

±1% +3counts
for range I > 0.5A

LCD Indication

CC, CV, Amp, Volt, Output ON-OFF

Protection

Short Circuit, Overload , Over Temperature, Tracking OVP

CE Approvals

LVD: EN 61010, EMC !: EN 55011

Cooling System

Natural Convection

Dimensions (W×H×D)

70 × 150 × 250mm / 2.8 × 6.0 × 9.8in

Weight

2Kgs / 4.4Lbs

Other Names:

NRP6016, NRP 6016