Datasheet Texas Instruments ADS8481IRGZT

ManufacturerTexas Instruments
SeriesADS8481
Part NumberADS8481IRGZT
Datasheet Texas Instruments ADS8481IRGZT

18 Bit 1MSPS parallel ADC W/Ref 48-VQFN -40 to 85

Datasheets

18-Bit 1-MSPS Pseudo-Diff Unipolar Input Micro Samp ADC w/Parallell Interface datasheet
PDF, 1.3 Mb, Revision: A, File published: Mar 27, 2006
Extract from the document

Prices

Status

Lifecycle StatusActive (Recommended for new designs)
Manufacture's Sample AvailabilityNo

Packaging

Pin4848
Package TypeRGZRGZ
Industry STD TermVQFNVQFN
JEDEC CodeS-PQFP-NS-PQFP-N
Package QTY250250
CarrierSMALL T&RSMALL T&R
Device MarkingADS8481I
Width (mm)77
Length (mm)77
Thickness (mm).9.9
Pitch (mm).5.5
Max Height (mm)11
Mechanical DataDownloadDownload

Parametrics

# Input Channels1
Analog Voltage AVDD(Max)5.25 V
Analog Voltage AVDD(Min)4.75 V
ArchitectureSAR
Digital Supply(Max)5.25 V
Digital Supply(Min)2.7 V
INL(Max)3.5 +/-LSB
Input Range(Max)4.1 V
Input TypePseudo-Differential,Single-Ended
Integrated FeaturesOscillator
InterfaceParallel
Multi-Channel ConfigurationN/A
Operating Temperature Range-40 to 85 C
Package GroupVQFN
Package Size: mm2:W x L48VQFN: 49 mm2: 7 x 7(VQFN) PKG
Power Consumption(Typ)220 mW
RatingCatalog
Reference ModeExt,Int
Resolution18 Bits
SINAD93 dB
SNR94 dB
Sample Rate (max)1MSPS SPS
Sample Rate(Max)1 MSPS
THD(Typ)-112 dB

Eco Plan

RoHSCompliant

Design Kits & Evaluation Modules

  • Evaluation Modules & Boards: ADS8481EVM
    ADS8481EVM Evaluation Module
    Lifecycle Status: Active (Recommended for new designs)

Application Notes

  • Determining Minimum Acquisition Times for SAR ADCs, part 1 (Rev. A)
    PDF, 227 Kb, Revision: A, File published: Nov 10, 2010
    This application report analyzes a simple method for calculating minimum acquisition times for successive-approximation register analog-to-digital converters (SAR ADCs). The input structure of the ADC is examined along with the driving circuit. The voltage on the sampling capacitor is then determined for the case when a step function is applied to the input of the driving circuit. Three different
  • Determining Minimum Acquisition Times for SAR ADCs, part 2
    PDF, 215 Kb, File published: Mar 17, 2011
    The input structure circuit of a successive-approximation register analog-to-digital converter (SAR ADC) incombination with the driving circuit forms a transfer function that can be used to determine minimum acquisition times for different types of applied input signals. This application report, which builds on Determining Minimum Acquisition Times for SAR ADCs When a Step Function is Applied to

Model Line

Manufacturer's Classification

  • Semiconductors > Data Converters > Analog-to-Digital Converters (ADCs) > Precision ADCs (<=10MSPS)