Datasheet Texas Instruments ADS1278

ManufacturerTexas Instruments
SeriesADS1278
Datasheet Texas Instruments ADS1278

24-Bit, 144kHz, 8-Ch, Simultaneous Sampling, Delta-Sigma ADC

Datasheets

Quad/Octal, Simultaneous Sampling, 24-Bit Analog-to-Digital Converters datasheet
PDF, 1.7 Mb, Revision: F, File published: Feb 17, 2011
Extract from the document

Prices

Status

ADS1278IPAPRADS1278IPAPTADS1278IPAPTG4
Lifecycle StatusActive (Recommended for new designs)Active (Recommended for new designs)Active (Recommended for new designs)
Manufacture's Sample AvailabilityYesNoYes

Packaging

ADS1278IPAPRADS1278IPAPTADS1278IPAPTG4
N123
Pin646464
Package TypePAPPAPPAP
Industry STD TermHTQFPHTQFPHTQFP
JEDEC CodeS-PQFP-GS-PQFP-GS-PQFP-G
Package QTY1000250250
CarrierLARGE T&RSMALL T&RSMALL T&R
Device MarkingADS1278ADS1278ADS1278
Width (mm)101010
Length (mm)101010
Thickness (mm)111
Pitch (mm).5.5.5
Max Height (mm)1.21.21.2
Mechanical DataDownloadDownloadDownload

Parametrics

Parameters / ModelsADS1278IPAPR
ADS1278IPAPR
ADS1278IPAPT
ADS1278IPAPT
ADS1278IPAPTG4
ADS1278IPAPTG4
# Input Channels888
Analog Voltage AVDD(Max), V5.255.255.25
Analog Voltage AVDD(Min), V4.754.754.75
ArchitectureDelta-SigmaDelta-SigmaDelta-Sigma
Digital Supply(Max), V2.22.22.2
Digital Supply(Min), V1.651.651.65
INL(Max), +/-LSB201.4201.4201.4
Input Range(Max), V5.255.255.25
Input TypeDifferentialDifferentialDifferential
Integrated FeaturesDaisy-ChainableDaisy-ChainableDaisy-Chainable
InterfaceSPISPISPI
Multi-Channel ConfigurationSimultaneous SamplingSimultaneous SamplingSimultaneous Sampling
Operating Temperature Range, C-40 to 105-40 to 105-40 to 105
Package GroupHTQFPHTQFPHTQFP
Package Size: mm2:W x L, PKG64HTQFP: 144 mm2: 12 x 12(HTQFP)64HTQFP: 144 mm2: 12 x 12(HTQFP)64HTQFP: 144 mm2: 12 x 12(HTQFP)
Power Consumption(Typ), mW530530530
RatingCatalogCatalogCatalog
Reference ModeExtExtExt
Resolution, Bits242424
SNR, dB111111111
Sample Rate (max), SPS144kSPS144kSPS144kSPS
Sample Rate(Max), MSPS0.1280.1280.128
THD(Typ), dB-108-108-108

Eco Plan

ADS1278IPAPRADS1278IPAPTADS1278IPAPTG4
RoHSCompliantCompliantCompliant

Application Notes

  • Using single-supply fully diff. amps with neg. input voltages to drive ADCs
    PDF, 105 Kb, File published: Nov 15, 2010
  • 4Q 2010 Issue Analog Applications Journal
    PDF, 1.3 Mb, File published: Nov 15, 2010
  • Analog Front-End Design for ECG Systems Using Delta-Sigma ADCs (Rev. A)
    PDF, 191 Kb, Revision: A, File published: Apr 13, 2010
    This document discusses the characteristics of electrocardiogram (ECG) signals and different front-endapproaches for ECG signal acquisition. The tradeoffs between different approaches and the effects on overall system design are discussed. The report also includes descriptions of potential implementations of the front-end architecture using the ADS1258 and ADS1278 and respective noise measuremen
  • Analog-to-Digital Converter Grounding Practices Affect System Performance (Rev. A)
    PDF, 69 Kb, Revision: A, File published: May 18, 2015
  • A Glossary of Analog-to-Digital Specifications and Performance Characteristics (Rev. B)
    PDF, 425 Kb, Revision: B, File published: Oct 9, 2011
    This glossary is a collection of the definitions of Texas Instruments' Delta-Sigma (О”ОЈ), successive approximation register (SAR), and pipeline analog-to-digital (A/D) converter specifications and performance characteristics. Although there is a considerable amount of detail in this document, the product data sheet for a particular product specification is the best and final reference.
  • Principles of Data Acquisition and Conversion (Rev. A)
    PDF, 132 Kb, Revision: A, File published: Apr 16, 2015

Model Line

Manufacturer's Classification

  • Semiconductors> Data Converters> Analog-to-Digital Converters (ADCs)> Precision ADCs (<=10MSPS)
EMS supplier