Datasheet AD8226 (Analog Devices) - 5

ManufacturerAnalog Devices
DescriptionWide Supply Range, Rail-to-Rail Output Instrumentation Amplifier
Pages / Page29 / 5 — AD8226. Data Sheet. ARZ, ARMZ. BRZ, BRMZ. Parameter. Conditions. Min. …
RevisionC
File Format / SizePDF / 720 Kb
Document LanguageEnglish

AD8226. Data Sheet. ARZ, ARMZ. BRZ, BRMZ. Parameter. Conditions. Min. Typ. Max. Unit

AD8226 Data Sheet ARZ, ARMZ BRZ, BRMZ Parameter Conditions Min Typ Max Unit

Text Version of Document

link to page 21 link to page 5 link to page 5
AD8226 Data Sheet ARZ, ARMZ BRZ, BRMZ Parameter Conditions Min Typ Max Min Typ Max Unit
Settling Time 0.01% 10 V step G = 1 25 25 µs G = 10 15 15 µs G = 100 40 40 µs G = 1000 350 350 µs Slew Rate G = 1 0.4 0.4 V/µs G = 5 to 100 0.6 0.6 V/µs GAIN G = 1 + (49.4 kΩ/RG) Gain Range 1 1000 1 1000 V/V Gain Error VOUT ±10 V G = 1 0.015 0.01 % G = 5 to 1000 0.15 0.1 % Gain Nonlinearity VOUT = −10 V to +10 V G = 1 to 10 RL ≥ 2 kΩ 10 10 ppm G = 100 RL ≥ 2 kΩ 75 75 ppm G = 1000 RL ≥ 2 kΩ 750 750 ppm Gain vs. Temperature2 G = 1 TA = −40°C to +85°C 5 1 ppm/°C TA = 85°C to 125°C 5 2 ppm/°C G > 1 TA = −40°C to +125°C −100 −100 ppm/°C INPUT VS = ±1.35 V to +36 V Input Impedance Differential 0.8||2 0.8||2 GΩ||pF Common Mode 0.4||2 0.4||2 GΩ||pF Input Operating Voltage Range3 TA = +25°C −VS − 0.1 +VS − 0.8 −VS − 0.1 +VS − 0.8 V TA = +125°C −VS − 0.05 +VS − 0.6 −VS − 0.05 +VS − 0.6 V TA = −40°C −VS − 0.15 +VS − 0.9 −VS − 0.15 +VS − 0.9 V Input Overvoltage Range TA = −40°C to +125°C +VS − 40 −VS + 40 +VS − 40 −VS + 40 V OUTPUT Output Swing RL = 2 kΩ to Ground TA = +25°C −VS + 0.4 +VS − 0.7 −VS + 0.4 +VS − 0.7 V TA = +125°C −VS + 0.4 +VS – 1.0 −VS + 0.4 +VS – 1.0 V TA = −40°C −VS + 1.2 +VS – 1.1 −VS + 1.2 +VS – 1.1 V RL = 10 kΩ to Ground TA = +25°C −VS + 0.2 +VS − 0.2 −VS + 0.2 +VS − 0.2 V TA = +125°C −VS + 0.3 +VS − 0.3 −VS + 0.3 +VS − 0.3 V TA = −40°C −VS + 0.2 +VS − 0.2 −VS + 0.2 +VS − 0.2 V RL = 100 kΩ to Ground TA = −40°C to +125°C −VS + 0.1 +VS − 0.1 −VS + 0.1 +VS − 0.1 V Short-Circuit Current 13 13 mA POWER SUPPLY Operating Range Dual-supply operation ±1.35 ±18 ±1.35 ±18 V Quiescent Current TA = +25°C 350 425 350 425 µA TA = −40°C 250 325 250 325 µA TA = +85°C 450 525 450 525 µA TA = +125°C 525 600 525 600 µA TEMPERATURE RANGE −40 +125 −40 +125 °C 1 The input stage uses pnp transistors; therefore, input bias current always flows out of the part. 2 The values specified for G > 1 do not include the effects of the external gain-setting resistor, RG. 3 Input voltage range of the AD8226 input stage. The input range depends on the common-mode voltage, the differential voltage, the gain, and the reference voltage. See the Input Voltage Range section for more information. Rev. C | Page 4 of 28 Document Outline Features Applications Pin Configuration General Description Revision History Specifications Absolute Maximum Ratings Thermal Resistance ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics Theory of Operation Architecture Gain Selection Reference Terminal Input Voltage Range Performance Across Temperature Recommendation for Best Performance Layout Common-Mode Rejection Ratio Over Frequency Power Supplies References Input Bias Current Return Path Input Protection Radio Frequency Interference (RFI) Applications Information Differential Drive Tips for Best Differential Output Performance Precision Strain Gage Driving an ADC Outline Dimensions Ordering Guide
EMS supplier