Datasheet AD8221 (Analog Devices) - 5

ManufacturerAnalog Devices
DescriptionPrecision Instrumentation Amplifier
Pages / Page13 / 5 — DLA LAND AND MARITIME. COLUMBUS, OHIO. 16236. V62/16619
File Format / SizePDF / 80 Kb
Document LanguageEnglish

DLA LAND AND MARITIME. COLUMBUS, OHIO. 16236. V62/16619

DLA LAND AND MARITIME COLUMBUS, OHIO 16236 V62/16619

Model Line for this Datasheet

Text Version of Document

TABLE I. Electrical performance characteristics – Continued. 1/ Test Symbol Conditions 2/ Temperature, Device Limits Unit T type A Min Max Voltage offset 4/ Input offset VOSI VS = 5 V to 15 V 25C 01 70 V -55C to +125C 150 Input offset average TC -55C to +125C 01 0.9 V/C temperature coefficient Output offset VOSO VS = 5 V to 15 V 25C 01 600 V -55C to +125C 1.2 mV Output offset average TC -55C to +125C 01 9 V/C temperature coefficient Offset RTI versus G = 1, VS = 2.3 V to 18 V 25C 01 90 dB supply (PSR) 100 typical G = 10, VS = 2.3 V to 18 V 100 120 typical G = 100, VS = 2.3 V to 18 V 120 140 typical G = 1000, VS = 2.3 V to 18 V 120 140 typical Input current Input bias current IIB 25C 01 2 nA 0.5 typical -55C to +125C 3.75 Input bias current TC -55C to +125C 01 11 typical pA/C average temperature coefficient See footnotes at end of table.
DLA LAND AND MARITIME
SIZE

CODE IDENT NO. DWG NO.
COLUMBUS, OHIO A 16236 V62/16619
REV PAGE 5
EMS supplier