Datasheet AD8426 (Analog Devices) - 4

ManufacturerAnalog Devices
DescriptionWide Supply Range, Rail-to-Rail Output Instrumentation Amplifier
Pages / Page28 / 4 — AD8426. Test Conditions/. A Grade. B Grade. Parameter. Comments. Min. …
File Format / SizePDF / 818 Kb
Document LanguageEnglish

AD8426. Test Conditions/. A Grade. B Grade. Parameter. Comments. Min. Typ. Max. Unit

AD8426 Test Conditions/ A Grade B Grade Parameter Comments Min Typ Max Unit

Model Line for this Datasheet

Text Version of Document

link to page 4 link to page 4 link to page 22
AD8426 Test Conditions/ A Grade B Grade Parameter Comments Min Typ Max Min Typ Max Unit
REFERENCE INPUT RIN 100 100 kΩ IIN 7 7 μA Voltage Range −VS +VS −VS +VS V Reference Gain to Output 1 1 V/V Reference Gain Error 0.01 0.01 % GAIN G = 1 + (49.4 kΩ/RG) Gain Range 1 1000 1 1000 V/V Gain Error VOUT ± 10 V G = 1 0.04 0.01 % G = 5 to 1000 0.3 0.1 % Gain Nonlinearity VOUT = −10 V to +10 V G = 1 to 10 RL ≥ 2 kΩ 20 20 ppm G = 100 RL ≥ 2 kΩ 75 75 ppm G = 1000 RL ≥ 2 kΩ 750 750 ppm Gain vs. Temperature2 G = 1 TA = −40°C to +85°C 5 1 ppm/°C TA = +85°C to +125°C 5 2 ppm/°C G > 1 TA = −40°C to +125°C −100 −100 ppm/°C INPUT VS = ±1.35 V to +36 V Input Impedance Differential 0.8||2 0.8||2 GΩ||pF Common Mode 0.4||2 0.4||2 GΩ||pF Input Operating Voltage TA = +25°C −VS − 0.1 +VS − 0.8 −VS − 0.1 +VS − 0.8 V Range3 TA = +125°C −VS − 0.05 +VS − 0.6 −VS − 0.05 +VS − 0.6 V TA = −40°C −VS − 0.15 +VS − 0.9 −VS − 0.15 +VS − 0.9 V Input Overvoltage Range TA = −40°C to +125°C +VS − 40 −VS + 40 +VS − 40 −VS + 40 V OUTPUT Output Swing RL = 2 kΩ to Ground TA = +25°C −VS + 0.4 +VS − 0.7 −VS + 0.4 +VS − 0.7 V TA = +125°C −VS + 0.4 +VS − 1.0 −VS + 0.4 +VS − 1.0 V TA = −40°C −VS + 1.2 +VS − 1.1 −VS + 1.2 +VS − 1.1 V RL = 10 kΩ to Ground TA = +25°C −VS + 0.2 +VS − 0.2 −VS + 0.2 +VS − 0.2 V TA = +125°C −VS + 0.3 +VS − 0.3 −VS + 0.3 +VS − 0.3 V TA = −40°C −VS + 0.2 +VS − 0.2 −VS + 0.2 +VS − 0.2 V RL = 100 kΩ to Ground TA = −40°C to +125°C −VS + 0.1 +VS − 0.1 −VS + 0.1 +VS − 0.1 V Short-Circuit Current 13 13 mA POWER SUPPLY Operating Range Dual-supply operation ±1.35 ±18 ±1.35 ±18 V Quiescent Current TA = +25°C 350 425 350 425 μA (Per Amplifier) TA = −40°C 250 325 250 325 μA TA = +85°C 450 525 450 525 μA TA = +125°C 525 600 525 600 μA TEMPERATURE RANGE −40 +125 −40 +125 °C 1 The input stage uses PNP transistors; therefore, input bias current always flows into the part. 2 The values specified for G > 1 do not include the effects of the external gain-setting resistor, RG. 3 Input voltage range of the AD8426 input stage. The input range depends on the common-mode voltage, the differential voltage, the gain, and the reference voltage. See the Input Voltage Range section for more information. Rev. 0 | Page 4 of 28 Document Outline FEATURES APPLICATIONS CONNECTION DIAGRAM GENERAL DESCRIPTION TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS DUAL-SUPPLY OPERATION Dynamic Performance Specifications SINGLE-SUPPLY OPERATION Dynamic Performance Specifications ABSOLUTE MAXIMUM RATINGS THERMAL RESISTANCE ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS TYPICAL PERFORMANCE CHARACTERISTICS THEORY OF OPERATION ARCHITECTURE GAIN SELECTION REFERENCE TERMINAL INPUT VOLTAGE RANGE LAYOUT Package Considerations Hidden Paddle Package Common-Mode Rejection Ratio over Frequency Power Supplies References INPUT BIAS CURRENT RETURN PATH INPUT PROTECTION RADIO FREQUENCY INTERFERENCE (RFI) APPLICATIONS INFORMATION PRECISION STRAIN GAGE DIFFERENTIAL DRIVE Differential Output Using Both AD8426 Amplifiers 2-Channel Differential Output Using a Dual Op Amp Tips for Best Differential Output Performance DRIVING A CABLE DRIVING AN ADC OUTLINE DIMENSIONS ORDERING GUIDE
EMS supplier