Datasheet Analog Devices ADR5044

ManufacturerAnalog Devices
SeriesADR5044

Precision Micropower Shunt Mode Voltage Reference Applications (4.096 Vout)

Datasheets

Datasheet ADR5040, ADR5041, ADR5043, ADR5044, ADR5045
PDF, 451 Kb, Language: en, Revision: D, File uploaded: Jul 25, 2018, Pages: 15
Precision Micropower Shunt Mode Voltage Reference Applications (5.0 Vout)
Extract from the document

Prices

Status

ADR5044AKSZ-REEL7ADR5044ARTZ-REEL7ADR5044BKSZ-REEL7ADR5044BRTZ-REEL7ADR5044WARTZ-R7ADR5044WBRTZ-R7
Lifecycle StatusProduction (Appropriate for new designs but newer alternatives may exist)Production (Appropriate for new designs but newer alternatives may exist)Production (Appropriate for new designs but newer alternatives may exist)Production (Appropriate for new designs but newer alternatives may exist)Production (Appropriate for new designs but newer alternatives may exist)Production (Appropriate for new designs but newer alternatives may exist)

Packaging

ADR5044AKSZ-REEL7ADR5044ARTZ-REEL7ADR5044BKSZ-REEL7ADR5044BRTZ-REEL7ADR5044WARTZ-R7ADR5044WBRTZ-R7
N123456
Package3-Lead SC703-Lead SOT-233-Lead SC703-Lead SOT-233-Lead SOT-233-Lead SOT-23
Pins333333
Package CodeKS-3RT-3KS-3RT-3RT-3RT-3

Parametrics

Parameters / ModelsADR5044AKSZ-REEL7ADR5044ARTZ-REEL7ADR5044BKSZ-REEL7ADR5044BRTZ-REEL7ADR5044WARTZ-R7ADR5044WBRTZ-R7
Initial Accuracy %(max), %0.10.10.10.10.10.1
Min Shunt Current(max), A50µ50µ50µ50µ50µ50µ
Operating Temperature Range, °C-40 to 125-40 to 125-40 to 125-40 to 125-40 to 125-40 to 125
Vnoise(typ), V p-p15.27µ15.27µ15.27µ15.27µ15.27µ15.27µ
Vout Tempco(max), ppm/°C757575757575
Vout(typ), V4.0964.0964.0964.0964.0964.096
Vref TypeShuntShuntShuntShuntShuntShunt

Eco Plan

ADR5044AKSZ-REEL7ADR5044ARTZ-REEL7ADR5044BKSZ-REEL7ADR5044BRTZ-REEL7ADR5044WARTZ-R7ADR5044WBRTZ-R7
RoHSCompliantCompliantCompliantCompliantCompliantCompliant

Other Options

ADR5040 ADR5041 ADR5043 ADR5045

Model Line

Manufacturer's Classification

  • Analog Functions > Shunt Voltage References