10/100 Base-T Single Port
Transformer Modules
With 1:1 Transmit Turns Ratios RoHS peak reflow temperature rating: 245�C
Compatible with Broadcom, Intel, Microtel, National
Semiconductor, ICS, and TDK Transceivers
Meets IEEE 802.3 specification
Electrical Specifications @ 25°C -Operating Temperature 0°C to 70°C
Differential to Common
Mode Rejection
Return Loss
(dB MIN)
(dB MIN @ 100 Ω) Insertion
Loss
(dB MAX) RoHS
Compliant
3
Part Number 0.1-100 MHz
H1012NL 4c H1086NL 4c HX1148NL 1, 4c Crosstalk
(dB TYP) Hipot
(Vrms MIN) 1-30 MHz 40 MHz 50 MHz 60-80 MHz 30 MHz 60 MHz 100 MHz 30 MHz 60 MHz 100 MHz -1.0 -20 -20 -18 -14 -42 -36 -33 -50 -40 -40 1500 -1.0 -22 -20 -18 -12 -45 -40 -35 -50 -40 -40 1500 -1.5 -18 -13.5 -11.5 -10 -42 -37 -33 -50 -40 -40 1500 Notes:
1. HX = Operating temperature: -40 + 85 C.
2. Unless specified, operating temperature is 0� to 70� C.
3. When ordering Tape & Reel packaging, add a "T" suffix to the end of the part
…