link to page 5 link to page 5 link to page 5 link to page 5 Data SheetADuM6132DIN V VDE V 0884-10 (VDE V 0884-10) INSULATION CHARACTERISTICS The ADuM6132 is suitable for reinforced electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by protective circuits. The asterisk (*) marking on the package denotes DIN V VDE V 0884-10 approval. Table 5. ParameterTest Conditions/CommentsSymbolValueUnit Installation Classification per DIN VDE 0110 For Rated Mains Voltage ≤ 150 V rms I to IV For Rated Mains Voltage ≤ 300 V rms I to III For Rated Mains Voltage ≤ 400 V rms I to II Climatic Classification 40/105/21 Pollution Degree (DIN VDE 0110, Table 1) 2 Maximum Working Insulation Voltage VIORM 560 V peak Input-to-Output Test Voltage, Method B1 VIORM × 1.875 = VPR, 100% production test, tm = 1 sec, VPR 1050 V peak partial discharge <5 pC Input-to-Output Test Voltage, Method A VPR After Environmental Tests Subgroup 1 VIORM × 1.6 = VPR, tm = 60 sec, partial discharge <5 pC 896 V peak After Input and/or Safety Test Subgroup 2 VIORM × 1.2 = VPR, tm = 60 sec, partial discharge <5 pC 672 V peak and Subgroup 3 Highest Allowable Overvoltage Transient overvoltage, tTR = 10 sec VTR 6000 V peak Safety-Limiting Values Maximum value allowed in the event of a failure (see Figure 2) Case Temperature TS 150 °C Side 1 Current IS1 555 mA Insulation Resistance at TS VIO = 500 V RS >109 Ω 600RECOMMENDED OPERATING CONDITIONS500mA)Table 6.( NTParameterRating400 Operating Temperature Range, TA −40°C to +85°C CURRE Input Supply Voltage, V 1 DD and VDDL 4.5 V to 5.5 V DD300 Channel A, Channel B Supply Voltage, 12.5 V to 17 V G V V 1 TIN DDA and VDDB A R200 Input Signal Rise and Fall Times 1 ms EOP Common-Mode Transient Immunity, −50 kV/µs to +50 kV/µs FE100 Input to Output A S Minimum Power-On Slew Rate (PSLEW), 1 V/ms 2 0 VDD and VDDL 050100150200 002 AMBIENT TEMPERATURE (°C) 1 All voltages are relative to their respective ground. 07393- 2 Figure 2. Thermal Derating Curve, Dependence of Safety-Limiting Values The ADuM6132 power supply may fail to properly initialize if VDD and VDDL are applied too slowly. The power supply slew rate must be faster than specified with Ambient Temperature per DIN V VDE V 0884-10 over the entire turn-on ramp. Power-on should start from a completely discharged state. Rev. B | Page 5 of 16 Document Outline Features Applications General Description Functional Block Diagram Table of Contents Revision History Specifications Electrical Characteristics Package Characteristics Regulatory Information Insulation and Safety-Related Specifications DIN V VDE V 0884-10 (VDE V 0884-10) Insulation Characteristics Recommended Operation Conditions Absolute Maximum Values ESD Caution Pin Configuration and Function Descriptions Typical Performance Characteristics Terminology Applications Information Typical Application Usage PCB Layout Thermal Analysis Undervoltage Lockout Propagation Delay-Related Parameters Magnetic Field Immunity Insulation Lifetime Outline Dimensions Ordering Guide