Datasheet TB67S112PG (Toshiba) - 7

ManufacturerToshiba
DescriptionBiCD Process Integrated Circuit Silicon Monolithic
Pages / Page15 / 7 — Absolute Maximum Ratings (Ta = 25°C). Caution) Absolute maximum ratings. …
File Format / SizePDF / 352 Kb
Document LanguageEnglish

Absolute Maximum Ratings (Ta = 25°C). Caution) Absolute maximum ratings. Operating Range (Ta=-40 to 85°C)

Absolute Maximum Ratings (Ta = 25°C) Caution) Absolute maximum ratings Operating Range (Ta=-40 to 85°C)

Model Line for this Datasheet

Text Version of Document

TB67S112PG
Absolute Maximum Ratings (Ta = 25°C)
Characteristics Symbol Rating Unit VM power supply VM (max) 50 V Output voltage (Note 3) VOUT (max) 50 V Output current (per one channel) IOUT (max) 1.5 A VIN(H) (max) 6.0 V Logic input voltage VIN(L) (max) -0.4 V ERR output pin voltage range VOD (max) 6.0 V ERR output pin inflow current range IOD (max) 20 mA 1.47 (Note 1) Power dissipation PD W 2.7 (Note 2) Operating temperature Topr -40 to 85 °C Storage temperature Tstg -55 to 150 °C Junction temperature Tj (max) 150 °C Note 1: Standalone. When Ta exceeds 25°C, derating with 11.8 mW/°C is necessary. Note 2: On PCB (size: 50 mm × 50 mm × 1.6 mm, Cu area: 50 %, single-side glass epoxy). When Ta exceeds 25°C, derating with 21.6 mW/°C is necessary. Note 3: OUT1 pin, OUT2 pin, and COM pin
Caution) Absolute maximum ratings
The absolute maximum ratings of a semiconductor device are a set of ratings that must not be exceeded, even for a moment. Do not exceed any of these ratings. Exceeding the rating(s) may cause device breakdown, damage or deterioration, and may result in injury by explosion or combustion. The value of even one parameter of the absolute maximum ratings should not be exceeded under any circumstances. The device does not have overvoltage detection circuit. Therefore, the device is damaged if a voltage exceeding its rated maximum is applied. Al voltage ratings, including supply voltages, must always be followed. The other notes and considerations described later should also be referred to.
Operating Range (Ta=-40 to 85°C)
Characteristics Symbol Test condition Min Typ. Max Unit VM power supply voltage VM ― 4.5 ― 47 V Output voltage (Note 1) VOUT ― 0 ― 50 V Output current IOUT Ta=25°C, per one channel ― 0.75 1.5 A Note: Please use the device with extra margin regarding the absolute maximum ratings. Moreover, please pay attention to the thermal conditions enough during use. Note 1: OUT1 pin, OUT2 pin, and COM pin 7 2019-07-08