Single/Dual/Quad, Low-Cost, SOT23, Micropower, Rail-to-Rail I/O Op Amps ELECTRICAL CHARACTERISTICS—TA = TMIN to TMAX (continued)
(VCC = +5.0V, VEE = 0V, VCM = 0V, VOUT = VCC / 2, SHDN = VCC, RL = 100kΩ tied to VCC / 2, unless otherwise noted.) (Note 3)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Input Common-Mode VCM Inferred from the CMRR test VEE VCC V Voltage Range Common-Mode MAX404_EU_ 60 CMRR VEE ≤ VCM ≤ VCC dB Rejection Ratio All other packages 65 Power-Supply PSRR 2.4V ≤ VCC ≤ 5.5V 70 dB Rejection Ratio Large-Signal Voltage AVOL (VEE + 0.2V) ≤ VOUT ≤ (VCC - 0.2V), RL = 25kΩ 68 dB Gain Output Voltage Swing VOH Specified as VCC - VOH, RL = 25kΩ 125 mV High Output Voltage Swing VOL Specified as VEE - VOL, RL = 25kΩ 75 mV
MAX4040–MAX4044
Low
Note 1:
Input bias current and input offset current are tested with VCC = +5.0V and +0.5V ≤ VCM ≤ +4.5V.
Note 2:
Tested for VEE ≤ VOUT ≤ VCC. Does not include current through external feedback network.
Note 3:
All devices are 100% tested at TA = +25°C. All temperature limits are guaranteed by design.
__________________________________________Typical Operating Characteristics
(VCC = +5.0V, VEE = 0, VCM = VCC / 2, SHDN = VCC, RL = 100kΩ to VCC / 2, TA = +25°C, unless otherwise noted.)
MAX4041/MAX4043 SUPPLY CURRENT PER AMPLIFIER SHUTDOWN SUPPLY CURRENT vs. TEMPERATURE PER AMPLIFIER vs. TEMPERATURE
20 5 18 SHDN = 0 µA) 16 MAX4040/44-01 VCC = +5.5V 4 MAX4040/44-01.5 µA) 14 12 3 10 VCC = +5.5V 8 VCC = +2.4V 2 SUPPLY CURRENT ( 6 VCC = +2.4V 4 1 SHUTDOWN SUPPLY CURRENT ( 2 0 0 -60 -40 -20 0 20 40 60 80 100 -60 -40 -20 0 20 40 60 80 100 TEMPERATURE (°C) TEMPERATURE (°C)