Universal Counter TTi TF830
- Frequency, period, pulse width, frequency ratio and event counter modes
- 5Hz to 1300MHz range, 0.001mHz resolution
- Reciprocal Counting measurement technique gives high resolution at all frequencies
- Low power, mains or battery operation
- Excellent sensitivity across the frequency range
- Optional addressable RS232 interface
Detailed Description
Specification
Functions |
Frequency |
Frequency range |
5Hz to 25MHz |
Input socket |
A |
||
Resolution |
0.001mHz to 100Hz (see Note 1) |
||
Frequency |
Frequency range |
20MHz to 1.3GHz |
|
Input socket |
B |
||
Resolution |
1Hz to 10kHz (see Note 1) |
||
Period |
Input socket |
A |
|
Frequency range |
5Hz to 25MHz |
||
Resolution |
10–7ns to 1us (see Note 1) |
||
Count |
Input socket |
A |
|
Counter range |
1 to 268435456 (228), only the least significant 8 digits shown |
||
Frequency range |
1Hz to at least 14MHz |
||
Minimum pulse width |
20ns |
||
Ratio A/B |
Frequency range |
A - 5Hz to 25MHz, B - 20MHz to 1.3GHz |
|
Resolution |
The answer is displayed with 8 significant digits irrespective of |
||
Pulse Width |
Input socket |
A |
|
Mode |
Falling to rising edge or rising to falling edge |
||
Range |
1us to 26s |
||
Resolution |
100ns |
||
Measurement time |
0.1s and 1s ranges determine the inter-measurement time. |
||
Note 1 |
|||
Input |
Input A |
Input impedance |
1MOhm//25pF |
Frequency range |
5Hz to 25MHz |
||
Sensitivity |
Sinewave 15mVrms 10Hz to 20MHz; pulse 40mV pk-pk 0Hz to 14MHz |
||
Trigger level |
Continuously adjustable by front panel control |
||
Max. permissible input voltage |
200Vdc; 250Vrms 50/60Hz reducing to 1Vrms above 1MHz |
||
Low pass filter |
Switchable 50kHz low pass noise filter |
||
Coupling |
AC |
||
Input B |
Input impedance |
50 Ohm nominal |
|
Frequency range |
20MHz to 1.3GHz |
||
Sensitivity |
10mVrms 20MHz to 700MHz, <50mVrms to 1.3GHz |
||
Max. permissible Input voltage |
250Vdc; 250Vrms 50/60Hz; 1Vrms 20MHz to 1.3GHz |
||
Coupling |
AC |
||
External |
Frequency |
10MHz |
|
Selection |
Automatic detection and change-over |
||
Sensitivity |
TTL/CMOS compatible, AC coupled |
||
Max. permissible input voltage |
5Vrms, 50V dc |
||
Timebase |
Oscillator |
10MHz Xtal |
|
Initial adjustment error |
<±1ppm at 23°C |
||
Temperature coefficient |
Typically less than ±0.3ppm/°C 18°C to 28°C, ±10ppm –20°C to 70°C |
||
Ageing rate |
<±5ppm/year |
||
RS232 Interface (TF830-RS232 ONLY) |
Addressable RS-232 interface, all functions remote-controllable including |
||
Power Requirements |
Battery type |
6 ‘C’ size disposable or rechargeable cells, (Alkaline cells) |
|
Battery life |
Typical figures TF830 - 200 hrs |
||
AC Input |
230 volts ±14% AC nominal or 115 volts ±14% AC nominal. |
||
Consumption |
8VA max. |
||
General |
Electrical Safety |
Complies with EN61010-1 |
|
EMC |
Complies with EN50081-1 and EN50082-1 |
||
Environmental operating range |
+5°C to +40°C, 20% to 80% RH |
||
Environmental storage range |
–20°C to +70°C |
||
Size |
257(W) × 224(D) × 88(H) excluding handle and feet |
||
Weight |
1.55kg(excluding batteries) |