Battery Charger Mean Well GC160A24-AD1

ManufacturerMean Well
SeriesGC160
Part NumberGC160A24-AD1

Power Adaptor with Charging Function

Prices

Detailed Description

Main Features:

  • 2 stage charging characteristic
  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • No load power consumption<1W
  • Meet EISA 2007 (Energy Independence and Security Act)
  • 3 pole AC inlet IEC320-C14
  • Class I power (with earth pin)
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Cooling by free air convection
  • Fully enclosed plastic case
  • 2 color LED indicator for charging status
  • Approvals: TUV / UL / CB / FCC / CE
  • 2 years warranty

Desktop Power Adaptor Mean Well GS160

Order No.

Output connector

Safety

GC160Axx-R7B (standard model)

4pin power din

TUV / CB / FCC / CE

GC160Axx-AD1 (optional model)

Anderson 1327 connector

UL / TUV / CB / FCC / CE

Specifications

Order No.

GC160A12-R7B

GC160A48-R7B

GC160A24-R7B

GC160A12-AD1

GC160A48-AD1

GC160A24-AD1

Output

Safety model No.

GC160A12

GC160A24

GC160A48

DC voltage (typ.)

13.6V

27.2V

54.4V

Recommended battery
capacity
Note.2

60 ~160Ah

30 ~ 90Ah

15 ~ 45Ah

Continuous output
current (typ.)

10A

5.89A

2.95A

Rated power

136W

160.2W

160.5W

LED indicator

Charging (CC) : RED
Floating charging (CV) : GREEN

Input

Voltage range
Note.3

85 ~ 264VAC
120 ~ 370VDC

Frequency range

47 ~ 63Hz

Power factor (typ.)

PF>0.95 / 230VAC
PF>0.98 / 115VAC at full load

Efficiency (typ.)

89%

92.5%

94%

AC current

1.85A / 115VAC
1A / 230VAC

Inrush current (max.)

120A / 230VAC

Leakage current (max.)

0.75mA / 240VAC

Protection

Overload
Note.4

90 ~ 110% rated output power

Protection type : Constant current limiting recovers automatically
after fault condition is removed

Short circuit

Protection type : Hiccup mode, recovers automatically after fault
condition is removed

Over voltage

105 ~ 135% rated output voltage

Protection type : Shut down o/p voltage, re-power on to recover

Over temperature

90 10 (RTH2) detect on inside ambient temperature

Protection type : Shut down o/p voltage, re-power on to recover

Environment

Working temp.

–30 ~ +70°C (Refer to output load derating curve)

Working humidity

20% ~ 90% RH non-condensing

Storage temp.

–40 ~ +85°C

Humidity

10 ~ 95% RH

Temp.

coefficient

0.03% / (0~50°C)

Vibration

10 ~ 500Hz, 2G 10min./1cycle,
period for 60min. each along X, Y, Z axes

Safety & EMC
(Note. 5)

Safety standards

UL1012 (for GC160Axx-AD1 only), TUV EN60950-1 approved

Withstand voltage

I/P-O/P: 3KVAC

Isolation resistance

I/P-O/P:100M Ohms / 500VDC / 25 °C / 70% RH

EMI conduction & radiation

Compliance to EN55022 class B,
FCC PART 15 class B / CISPR22 class B

Harmonic current

Compliance to EN61000-3-2,3

EMS immunity

Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level,
criteria A

Others

Dimension

175×72×35mm (L×W×H)

Packing

0.7Kg; 20pcs/ 15Kg/ 0.85CUFT

Note

  1. All parameters NOT specially mentioned are measured at 230VAC input,
    rated load and 25°C of ambient temperature
  2. This is MeanWell's suggested range, please consult your battery manufacturer
    for their suggestions about maximum charging current limitation
  3. Derating may be needed under low input voltage
  4. Constant current operation region is within 50~100% rated output voltage
  5. The power supply is considered a component which will be installed into a final
    equipment. The final equipment must be re-confirmed that it still meet EMC directives

Outline Drawing

GC160 outline drawings
Click to enlarge

Other Names:

GC160A24AD1, GC160A24 AD1