Battery Charger Mean Well GC160A24-AD1
Manufacturer | Mean Well |
Series | GC160 |
Part Number | GC160A24-AD1 |
Power Adaptor with Charging Function
Prices
Detailed Description
Main Features:
- 2 stage charging characteristic
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- No load power consumption<1W
- Meet EISA 2007 (Energy Independence and Security Act)
- 3 pole AC inlet IEC320-C14
- Class I power (with earth pin)
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Fully enclosed plastic case
- 2 color LED indicator for charging status
- Approvals: TUV / UL / CB / FCC / CE
- 2 years warranty
Order No. |
Output connector |
Safety |
GC160Axx-R7B (standard model) |
4pin power din |
TUV / CB / FCC / CE |
GC160Axx-AD1 (optional model) |
Anderson 1327 connector |
UL / TUV / CB / FCC / CE |
Specifications
Order No. |
GC160A12-R7B |
GC160A48-R7B |
GC160A24-R7B |
|
GC160A12-AD1 |
GC160A48-AD1 |
GC160A24-AD1 |
||
Output |
Safety model No. |
GC160A12 |
GC160A24 |
GC160A48 |
DC voltage (typ.) |
13.6V |
27.2V |
54.4V |
|
Recommended battery |
60 ~160Ah |
30 ~ 90Ah |
15 ~ 45Ah |
|
Continuous output |
10A |
5.89A |
2.95A |
|
Rated power |
136W |
160.2W |
160.5W |
|
LED indicator |
Charging (CC) : RED |
|||
Input |
Voltage range |
85 ~ 264VAC |
||
Frequency range |
47 ~ 63Hz |
|||
Power factor (typ.) |
PF>0.95 / 230VAC |
|||
Efficiency (typ.) |
89% |
92.5% |
94% |
|
AC current |
1.85A / 115VAC |
|||
Inrush current (max.) |
120A / 230VAC |
|||
Leakage current (max.) |
0.75mA / 240VAC |
|||
Protection |
Overload |
90 ~ 110% rated output power |
||
Protection type : Constant current limiting recovers automatically |
||||
Short circuit |
Protection type : Hiccup mode, recovers automatically after fault |
|||
Over voltage |
105 ~ 135% rated output voltage |
|||
Protection type : Shut down o/p voltage, re-power on to recover |
||||
Over temperature |
90 10 (RTH2) detect on inside ambient temperature |
|||
Protection type : Shut down o/p voltage, re-power on to recover |
||||
Environment |
Working temp. |
–30 ~ +70°C (Refer to output load derating curve) |
||
Working humidity |
20% ~ 90% RH non-condensing |
|||
Storage temp. |
–40 ~ +85°C |
|||
Humidity |
10 ~ 95% RH |
|||
Temp. coefficient |
0.03% / (0~50°C) |
|||
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, |
|||
Safety & EMC |
Safety standards |
UL1012 (for GC160Axx-AD1 only), TUV EN60950-1 approved |
||
Withstand voltage |
I/P-O/P: 3KVAC |
|||
Isolation resistance |
I/P-O/P:100M Ohms / 500VDC / 25 °C / 70% RH |
|||
EMI conduction & radiation |
Compliance to EN55022 class B, |
|||
Harmonic current |
Compliance to EN61000-3-2,3 |
|||
EMS immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, |
|||
Others |
Dimension |
175×72×35mm (L×W×H) |
||
Packing |
0.7Kg; 20pcs/ 15Kg/ 0.85CUFT |
|||
Note |
|
Outline Drawing
Other Names:
GC160A24AD1, GC160A24 AD1