Datasheet ADCMP371-KGD (Analog Devices) - 4

ManufacturerAnalog Devices
DescriptionGeneral Purpose Comparators
Pages / Page6 / 4 — ADCMP371-KGD. Known Good Die. ABSOLUTE MAXIMUM RATINGS. Table 2. …
File Format / SizePDF / 136 Kb
Document LanguageEnglish

ADCMP371-KGD. Known Good Die. ABSOLUTE MAXIMUM RATINGS. Table 2. Parameter. Rating. ESD CAUTION

ADCMP371-KGD Known Good Die ABSOLUTE MAXIMUM RATINGS Table 2 Parameter Rating ESD CAUTION

Model Line for this Datasheet

Text Version of Document

ADCMP371-KGD Known Good Die ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted. Stresses at or above those listed under Absolute Maximum
Table 2.
Ratings may cause permanent damage to the product. This is a
Parameter Rating
stress rating only; functional operation of the product at these VCC −0.3 V to +6 V or any other conditions above those indicated in the operational IN+, IN− −0.3 V to +25 V section of this specification is not implied. Operation beyond OUT −0.3 V to V the maximum operating conditions for extended periods may CC + 0.3 V affect product reliability. Operating Temperature Range −40°C to +85°C Storage Temperature Range −65°C to +150°C
ESD CAUTION
θJA Thermal Impedance, SC70 146°C/W Lead Temperature Soldering (10 sec) 300°C Vapor Phase (60 sec) 215°C Infrared (15 sec) 220°C Rev. 0 | Page 4 of 6 Document Outline FEATURES APPLICATIONS GENERAL DESCRIPTION FUNCTIONAL BLOCK DIAGRAM TABLE OF CONTENTS REVISION HISTORY SPECIFICATIONS ABSOLUTE MAXIMUM RATINGS ESD CAUTION PIN CONFIGURATION AND FUNCTION DESCRIPTIONS OUTLINE DIMENSIONS DIE SPECIFICATIONS AND ASSEMBLY RECOMMENDATIONS ORDERING GUIDE