Product brochure RTM3000 oscilloscope (Rohde&Schwarz) - 3

ManufacturerRohde&Schwarz
DescriptionOscilloscope
Pages / Page22 / 3 — Benefits and key features. The best choice for power. See small signal …
Revision04.02
File Format / SizePDF / 10.7 Mb
Document LanguageEnglish

Benefits and key features. The best choice for power. See small signal details in the presence of large. signals

Benefits and key features The best choice for power See small signal details in the presence of large signals

Text Version of Document

link to page 10 link to page 10 link to page 12 link to page 12 link to page 12 link to page 13 link to page 13 link to page 14 link to page 14 link to page 4 link to page 4 link to page 4 link to page 4 link to page 4 link to page 5 link to page 5 link to page 5 link to page 5 link to page 5 link to page 7
Benefits and key features The best choice for power See small signal details in the presence of large
▷ page 10
signals
❙10-bit vertical resolution
Spectrum analysis: identify interactions between
❙500 µV/div: full measurement bandwidth and low noise
time and frequency
▷ page 4 ▷ page 12
Capture more time at full bandwidth Protocol analysis: efficiently debug serial buses
❙40 Msample standard and 80 Msample interleaved ▷ page 13 ❙Segmented memory: 400 Msample with history function ❙Maintains fast sampling rates at all times
The right probe for the best measurement
▷ page 5 ▷ page 14
10.1" high-resolution capacitive touchscreen with gesture support
❙10.1" high-resolution capacitive touch display ❙Gesture support like on your smartphone ❙Fast access to important tools ▷ page 6
Choose your Rohde & Schwarz embedded oscilloscope R&S®RTC1000 R&S
®
RTB2000 R&S®RTM3000 R&S®RTA4000 Number of oscilloscope
2 2/4 2/4 4
channels Bandwidth in MHz
50, 70, 100, 200, 300 70, 100, 200, 300 100, 200, 350, 500, 1000 200, 350, 500, 1000
Max. sampling rate in
1/channel, 2 interleaved 1.25/channel, 2.5 interleaved 2.5/channel, 5 interleaved 2.5/channel, 5 interleaved
Gsample/s Max. memory depth in
1/channel, 2 interleaved 10/channel, 20 interleaved; 40/channel, 80 interleaved; 100/channel, 200 interleaved;
Msample
160 Msample (optional) 400 Msample (optional) 1 Gsample (standard) segmented memory segmented memory segmented memory
Timebase accuracy in
50 2.5 2.5 0.5
ppm Vertical bits (ADC)
8 10 10 10
Min. input sensitivity
1 mV/div 1 mV/div 500 µV/div 500 µV/div
Display
6.5", 10" capacitive touch, 10" capacitive touch, 10" capacitive touch, 640 × 480 pixel 1280 × 800 pixel 1280 × 800 pixel 1280 × 800 pixel
Update rate
10 000 waveforms/s 50 000 waveforms/s 64 000 waveforms/s 64 000 waveforms/s
MSO
8 channels, 1 Gsample/s 16 channels, 2.5 Gsample/s 16 channels, 5 Gsample/s 16 channels, 5 Gsample/s
Protocol (optional)
I2C, SPI, UART/RS-232/ I2C, SPI, UART/RS-232/ I2C, SPI, UART/RS-232/RS-422/ I2C, SPI, UART/RS-232/ RS-422/RS-485, CAN, LIN RS-422/RS-485, CAN, LIN RS-485, CAN, LIN, audio (I²S/ RS-422/RS-485, CAN, LIN, LJ/RJ/TDM), ARINC, MIL audio (I²S), ARINC, MIL
Generator(s)
1 generator, 4-bit pattern 1 ARB, 4-bit pattern 1 ARB, 4-bit pattern generator 1 ARB, 4-bit pattern generator generator generator
Math
+, –, *, /, FFT (128k points) +, –, *, /, FFT (128k points) +, –, *, /, FFT (128k points), +, –, *, /, FFT (128k points), 21 advanced functions 21 advanced functions
Rohde & Schwarz probe
– – standard standard
interface RF capability
FFT FFT spectrum analysis spectrum analysis
Rohde & Schwarz
R&S®RTM3000 Oscilloscope
3
RTM3000_bro_en_5214-9144-12_v0402.indd 3 01.03.2018 08:45:58