Desktop Power Adaptor Mean Well GS160A48-R7B

ManufacturerMean Well
SeriesGS160
Part NumberGS160A48-R7B

Main Features:

Prices

Detailed Description

  • Universal AC input / Full range
  • 3 pole AC inletl EC320-C14
  • Built-in active PFC function, PF>0.95
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Fully enclosed plastic case
  • Approvals: UL / CUL / TUV / BSMI / CCC / CB / FCC / CE
  • Class I power (with earth pin)
  • LED indicator for power on
  • No load power consumption <0.5W
  • ENERGY STAR compliant
  • Meet EISA 2007 (Energy Independence and Security Act)
  • 2 years warranty

Desktop Power Adaptor Mean Well GS160A48-R7B

Specifications

Order No.

GS160A12-R7B

GS160A15-R7B

GS160A20-R7B

GS160A24-R7B

GS160A48-R7B

Output

Safety model No.

GS160A12

GS160A15

GS160A20

GS160A24

GS160A48

DC voltage

12V

15V

20V

24V

48V

Rated current

11.5A

9.6A

8A

6.67A

3.34A

Current range

0-11.5A

0-9.6A

0-8A

0-6.67A

0-3.34A

Rated power (max.)

138W

144W

160W

160W

160W

Ripple & noise (max.)
(Note.2)

80mVp-p

100mVp-p

150mVp-p

180mVp-p

240mVp-p

Voltage tolerance
(Note.3)

±5.0%

±5.0%

±4.0%

±3.0%

±3.0%

Line regulation
(Note.4)

±1.0%

±1.0%

±1.0%

±1.0%

±1.0%

Load regulation

±5.0%

±5.0%

±4.0%

±3.0%

±3.0%

Setup, rise time
(Note.6)

2000ms, 20ms /230VAC
2500ms, 20ms/ 115VAC at full load

Hold up time (Typ.)

20ms/230VAC
20ms/115VAC at full load

Input

Voltage range
(Note.7)

85-264VAC
120-370VDC

Frequency range

47-63Hz

Power factor (Typ.)

PF>0.95/230VAC
PF>0.98/115VAC at full load

Efficiency (Typ.)

89%

90%

92%

92.5%

94%

AC current

1.85A/115VAC
1A/230VAC

Inrush current (max.)

120A/230VAC

Leakage current (max.)

0.75mA/240VAC

Protection

Overload

105-135% rated output power

Protection type: Hiccup mode, recovers automatically after fault condition is removed

Over voltage

105-135% rated output voltage

Protection type : Shut down o/p voltage, re-power on to recover

Over temperature

90 °C ±10 °C (RTH2) detect on inside ambient temperature

Protection type : Shut down o/p voltage, re-power on to recover

Environment

Working temp.

–30 - +70°C (Refer to output load derating curve)

Working humidity

20% - 90% RH non-condensing

Storage temp.,
humidity

–20 - +85°C, 10-95%RH

Temp.

Coefficient

±0.03%/°C (0~50°C)

Vibration

10 - 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes

Safety & EMC
(Note. 5)

Safety standards

UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943 approved

Withstand voltage

l/P-O/P: 3KVAC

Isolation resistance

l/P-O/P:100M Ohms / 500VDC/25°C/70% RH

EMI conductions
radiation

Compliance to EN55022(CISPR22), EN61204-3 class B,
CNS13438 class B, GB9254-1 class B

Harmonic current

Compliance to EN61000-3-2,3, GB17625.1

EMS immunity

Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A

Others

MTBF

290.3Khrs min. MIL-HDBK-217°F(25 °C)

Dimension

175×72×35mm (L×W×H)

Packing

0.66Kg; 20pcs/ 14.2Kg/ 0.85CUFT

Note

  1. All parameters are specified at 230VAC input, rated load, 25 C 70% RH ambient.
  2. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
  3. Tolerance: includes set up tolerance, line regulation, load regulation.
  4. Line regulation is measured from low line to high line at rated load.
  5. he power supply is considered a component which will be installed into a final equipment.
  6. The final equipment must be re EMC directives.
  7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead
    to increase of the set up
  8. Derating may be needed under low input voltage. Please check the derating curve for more details.
  9. -confirmed that it still meets time.

Outline Drawing

Other Names:

GS160A48R7B, GS160A48 R7B